Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Delivery - Oase PondJet Eco Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für PondJet Eco:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
Translation of the original Operating Instructions
Information about these operating instructions
Welcome to OASE Living Water. You made a good choice with the purchase of this product PondJet Eco.
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
Ensure that all work on and with this unit is only carried out in accordance with these instructions.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new
owner.
Symbols used in these instructions
GB
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate
measures are not taken.
Risk of personal injury caused by a general source of danger
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate
measures are not taken.
Important information for trouble-free operation.
 A
Reference to one or more figures. In this example: Reference to Fig. A.
Reference to another section.

Scope of delivery

 A
PondJet Eco
1
Float
2
Nozzle body with integrated multifunctional nozzle
(multifunctional nozzle is closed off with a cover disk and plug)
3
Pump
4
Retaining brace for pump
5
Adapter for connection of pump to nozzle body
6
Flat seal 40 × 30 × 2 mm, positioned between adapter (5) and pump (3)
7
M8 × 130 mm hexagon screws, washers and self-locking nuts
8
M6 × 35 mm Allen screws, tooth lock washers and nuts
9
M8 × 40 mm stud bolts, washers and nuts
Product Description
Properties
 Floating fountain for flexible installation in ponds and lakes, suitable for all ground conditions.
 Multifunctional nozzle already integrated.
 Simple installation thanks to float function.
 Also ideal for temporary use, e.g. for events.
 Impressive water display with a height and width of up to 3 m.
 Additional nozzle patterns and lighting set available as accessories.
Environmental Function Control (EFC)
If there is a blockage in the pump when it is switched on or if it runs dry, a pre-programmed self-test (Environmental
Function Control - EFC) is automatically performed. The pump tries to start up at regular intervals and run through dif-
ferent speeds to overcome the fault (dry run or blockage). The pump switches off after approx. 2 minutes of un-
successful start-up attempts and repeats the self-test after approx. 30 minutes.
Dynamic Function
Different values for the pump flow rates are pre-programmed in the pump control system to allow a dynamic fountain
pattern with changing heights and diameters. When the Dynamic Function is activated, the pump is continuously con-
trolled with these values.
- EN -
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis