Dexxo Pro io
6 - MAINTENANCE
6.1 Replacing the bulb in the light unit
[1] [2].Remove the light cover.
[3] [4]. Unscrew and replace the defective light bulb.
[5] [6] [7]. Refit the light cover.
Use a 230 V 40 W E14 socket light bulb.
6.2 Checking
> The obstacle detection function
Every month, check that the door reverses direction when an obstacle prevents
the door from closing (at least 50 mm above floor level).
> The safety mechanisms (cells, pedestrian door contact, sensor
bar)
Check correct operation every month (See section 4.2).
> The back-up battery
To ensure optimum battery life, we recommend that the power to the motor
is switched off and the door is operated for a number of cycles using battery
power (three times a year).
6.3 Replacing a Keytis remote control battery
6.4
Replacing a Keygo remote control battery
Copyright © 2012 Somfy SAS. All rights reserved
1.5V LR3
7 - TECHNICAL SPECIFICATIONS
Basic technical
Dexxo Pro 800
specifications
Mains power supply
Power consumption on standby
Max. power consumption
Traction force
Use
50 cycles per day with a high performance
Number of channels that can be
Situo io/Keygo io: 9
memorised
Somfy radio frequency
Integrated light
Remote controlled lighting
Operating temperature
Dexxo Pro 1000
230 V - 50 Hz
5 W
600 W (with 500 W remote controlled
lighting)
800 N
1000 N
20 cycles per day with a standard rail
(tested for 36,500 cycles)
rail (tested for 90,000 cycles)
Others: unlimited
868 - 870 MHz
230 V / 40 W max. E14 socket
230 V / 500 W max. Class 2
-20 °C / +60 °C
6