1 TECHNICAL CHARACTERISTICS
Number of powder containers
Capacity of each container,
approx.
Capacity
of
water
tank,
approx
Dimensions:
width
depth
height
Net weight, approx.
Gross weight, approx.
IMPORTANT
Read electrical ratings written on the data plate of the
individual units; the data plate is adhered on the back
wall of the water tank compartment.
The serial number of the unit (preceded by the symbol #)
is on the data plate.
Data plate specifications will always supersede the
information in this manual.
Specifications are subject to change without notice.
2 INTRODUCTION
Please read all sections of this manual thoroughly to familiarize
yourself with all aspects of the unit.
Like all mechanical products, this machine will require cleaning
and maintenance. Besides, dispenser working can be
compromised by operator's mistakes during disassembly and
cleaning. It is strongly recommended that personnel responsible
for the equipment's daily operations, disassembly, cleaning,
sanitizing and assembly, go through these procedures in order
t o b e p r o p e r l y t r a i n e d a n d t o m a k e s u r e t h a t n o
misunderstandings exist.

3 INSTALLATION

1 Remove the corrugate container and packing materials and
keep them for possible future use.
2 Inspect the uncrated unit for any possible damage. If
damage is found, call the delivering carrier immediately to file a
claim.
3 Install the unit on a counter top that will support the
combined weight of dispenser and product.
4 Before plugging the unit in, check if the voltage is the same
as that indicated on the data plate. Plug the unit into a
grounded, protected, single phase electrical supply according
to the applicable electrical codes and the specifications of your
machine. When the unit has no plug, install a proper grounded
plug, in compliance with electrical codes in force in your area,
suitable to at least 10 Amp 250 Volt (220-230 Volts 50-60 Hz
areas) and 20 Amp 250 Volt (100-115 Volts 50-60 Hz areas)
applications. Should you prefer to connect the unit directly to
the mains, connect the supply cord to a 2-pole wall breaker,
whose contact opening is at least 3 mm. Do not use extension
M20/1 M20/2 M27/2 M27/3
n
1
2
2
cc
2000
1200
2000
1200
cc
2000
2000
3000
3000
cm
20
20
27
cm
33
33
33
cm
57
57
57
kg
11
11
13
kg
12
12
14
cords.
ATTENTION
3
Failure to provide proper electrical ground according to
applicable electrical codes could result in serious shock
hazard.
5 The unit doesn't come pre sanitized from the factory. Before
serving products, the dispenser must be disassembled,
cleaned and sanitized according to this handbook instructions
( s e e p a r a g r a p h 6 C L E A N I N G A N D S A N I T I Z I N G
PROCEDURES).
27
33
57
IMPORTANT
14
Install
the dispenser so that the plug is easily
accessible.
15
4 TO OPERATE SAFELY
1 Do not operate the dispenser without reading this
operator's manual.
2 Do not operate the dispenser unless it is properly
grounded.
3 Do not use extension cords to connect the dispenser.
4 Do not operate the dispenser unless all panels and covers
are restrained with screws.
5 Do not put objects or fingers in panels louvers and faucet
outlet.
5 OPERATING PROCEDURES
5. 1 DISPENSER SET UP
1 Clean and sanitize the unit according to the instructions in
this manual (see paragraph 6 CLEANING AND SANITIZING
PROCEDURES).
2 Remove the drip tray, product outlets and then the front
10