A STONE SPACE NOT BEEN FILLED COMPLETELY IS A FIRE HAZARD!
The use of ceramic stones that are light, porous and of the same size is prohibited, as they can
cause excessive heating and break the resistors. Likewise, soft soap-stones shall not be used in
the sauna heater.
ALWAYS INSPECT THE STEAM ROOM, BEFORE SWITCHING ON THE HEATER!
Figure 5.
4. CONTROL UNIT AND MAINS SWITCH:
- The control unit shall be installed in the steam room or in the dressing room.
- The installation height of the control unit is a maximum of 80 cm and a minimum of 60 cm from
the side of the heater (See image 5)
- Attach the control unit to the wall using screws (2 x 3.5 *15)
- The length of the control unit cable is 3 metres.
The cable must not be inserted into the heater's connecting box.
- The mains switch is located in the front on the lower part of the heater (See figure 6).
NOTE! In case of malfunction, the sauna heater will be switched off.
4.1 OVERVIEW
- The heater is switched on and off by
toggling the I/O button. Restart will not
be possible until in about 5 seconds after
switching off.
- The SET button is used for setting the
following parameters: Preset timing,
power-on time and temperature.
The setting is carried out using the +/-
buttons. During set-up, a LED flashes to
indicate the parameter being set, with the
respective value being displayed on the
screen.
- The settings of the power-on time and the
temperature remain in memory even after
a short outage of power. After a longer
blackout the default values will be applied
The preset timing will always be reset after
the use.
- The On/Off LED is illuminated red
whenever the heating elements are turned
on, at all other times it is green.
During the preset time, the On/Off LED is
not illuminated.
min. 60 cm
Figure 7.
Figure 6.
On/Off signal light
Preset timing (yellow)
Power-on time (green)
Output (röd)
SET
Preset timing max 8h
Power-on time max 4h
Temperature
1-16
(n. 60–110°C)