Installation Instructions for the Economic

General instructions

Preparation
Installation
Repairs
Technical details Economic
General instructions
The Economic is tested in accordance with the
international EN 13240 standardization, and has an extra
additional standardization for optimally environment-
friendly heating devices related to flue gases (Section
15a B-Vg. Des BmfWA). The stove can be connected to
a flue tube to which several stoves are connected. The
flue tube has a diameter of 150 millimetres.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee if
the Economic is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
• Arcades and corridors accessible to the public.
• Stairwells, except in buildings with no more than 2
dwellings.
• Spaces where highly flammable or explosive materials
are used.
• Spaces where an exhaust system is used or where a
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney flue
Install ventilation grills to avoid cracks and discoloration
in plasterwork.
Before placing the stove you must observe the following
points:
• If the stove is connected to an existing chimney, you
must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company.
Any cut-off valves or stop valves must be removed.
• The flue tube of the stove must be connected with the
chimney without diversions.
24
24
24
25
27
28
• The underpressure in the chimney must be at least 12
Pa or 0.12 mbar.
• The chimney flue must always end up in outlet area 1
(see the drawing and the table on page 25)
• At the time of placing the stove, the chimney flue
must be clean, leak-proof and without obstructions,
and must have a diameter of 150 mm.
• Any bends in the flue tube must not exceed 45
degrees.
• Ensure that the chimney tube can discharge the flue
gases adequately, properly and safely.
• The values for calculating the chimney tube is given
in the section on Technical Information, page 25.
Fire Safety
For reasons of fire safety it is important to observe the
following instructions before installing the fireplace.
1. If the floor around the stove is made of combustible
material, you must use a floor slab.
The floor slab must measure at least:
- 50 cm from the stove on the front side of the door
- 30 cm from the stove on the sides of the door.
2. Keep a distance of at least 80 cm between the fireplace
and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects.