Technical details Economic
Technical details
Door latch
Nominal capacity*
Diameter tube for combustion gases
Maximum lumber supply in the stove
Maximum brown coal supply
Volume of the combustion chamber
Surface bottom of combustion chamber
* a nominal heat of 7 kW is obtained with a chimney draught of 0.12 mbar
Fuel
Maximum supply
Primary air valve
Secondary air outlet
Fuel burning period
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When door is closed
Flue gas quantity
Flue gas temperature
Pre-pressure
Yield
CO at 13% O2
Particulate matter
Certificate Institute 1625. Test standard EN 13229. Test report no. RRF-400169
28
Ba
I/II
7
kW
150
mm
3
kg
3
kg
0.08
m3
0.2
m2
wood logs, 30 x 10 cm
3 pieces
max.
max.
about 1 hour
logs
4,2
g/s
330
˚C
0.12
mbar
78.7
%
0.06
%
--
mg/m3
brown coal
4 pieces
max.
max.
about 1 hour
brown coal
12,2
g/s
298
°C
0,12
mbar
79,3
%
0,09
%
--
mg/m3