5 - OPERATING INSTRUCTIONS
2.3. - WINTER FUNCTIONING BY MEANS OF THE MECHANICAL CONTROL PANEL (HEATING
BY MEANS OF THE REVERSAL CYCLE - RC MODEL)
Switch on the system selecting "HEAT". Turn the thermostat knob towards "+" until the compres-
sor starts running. Select the fan speed. When in the cabin there is the desired temperature, turn
the thermostat knob towards "-" anticlockwise until the compressor stops. As indicated in 2.2,
switching off the compressor, the air-conditioner makes the ambient air circulate without warming
it up. If the sea water temperature is above 18° C, the high pressure safety device will snap. Switch
off the system and then switch it on again and select a higher fan speed value.
3 - IMPORTANT NOTES
3.1 - INSTALLATION IN THE ENGINE COMPARTMENT (only for SPLIT models)
The air-conditioner use can cause the going off of sparks (switches, relays, etc...) To avoid the risk
of explosions, it is necessary to start the smoke-exhauster 10 minutes before switching on the air-
conditioning system and they must suck up the smoke as long as the air-conditioner runs.
3.2 - TROUBLESHOOTING
Only the qualified staff can execute the troubleshooting respecting the safety regulations.
3. 3 - MULTIPPLE INSTALLATIONS
It is necessary to space out the switching on delays of the air-conditioners at least of 5 seconds
one from another.
4 - MAINTENANCE
For an efficient functioning of the air-conditioner, follow these advices about checks and mainte-
nance. Intervention times can change according to the installation place, the pollution and the
installation use.
- Clean the sea water filter every week.
- Clean the air filter every month.
- Clean the condensation outlet pipe every four months.
- Clean the condensation collection tray every year.
- Clean the water intake every year (operation to be executed in shipyard).
- Change the batteries (only for VEGA MK II with remote control device) every year.
These operations must be executed only after having switched off the air-conditioner and only by
the qualified staff.
Don't check the electrical circuit if none can bring help in case of accident.
- Check hydraulic connections every year.
- Consult also "Installation Manual".
4.1 - CONDENSATION WATER AND ITS OUTLET
During the cooling cycle air-conditioners produce much
condensation water, above all when it is damp. Check
periodically that there are no leaks or obstructions on the
condensation outlet and that the condensation water
drains regularly. Pour in the condensation tray some
water and check that it flows currently. If the condensa-
tion water drains to the bilge, it is better to let it flow
towards a limited space and let it drain continually to
avoid stagnation that can cause unpleasant smells.