Current overload
Protection , the motor
electrical is overload
E4
Incline self-learning fault
Incline sensor error
E5
Explosion-Proof Protection
:Some unusual condition
of power or voltage that
cause damage to the
E6
motor drive circuit.
E7
The upper EEPROM is
E8
The lower EEPROM is
Remark: After replacing lower controller and replacing the parts for E5/E6 issue, please follow
steps below to re-calibrate the machine
1.1 Press PROG and SPE+ KEY at the same time and POWER UP or reset SAFETY KEY entry. After
entry, LCD will run display testing, all segment will lights up to show according.
1.2 If press START KEY, the computer will take the default data to calibrate and save into EEPROM.
1.3 Press MODE to entry unit setting mode
1.4 Press MODE to entry the setting mode of WHEEL SIZE
1.5 Press MODE to entry the setting mode of MIN SPEED
1.6 Press MODE to entry the setting mode of MAX SPEED
1.7 Press MODE to entry the setting mode of MAX ELEVATION
1.8 Press START KEY to entry SPEED CALIBRATE, It will show "CAL" in the window of SPEED in
sprinkle. After calibrate will back to IDLE MODE automatically.
recorded faulty
recorded faulty
the controller has the smell and change the controller if
have
Stop and go into fault status, computer buzzer will ring 3
tones and shows fault code"E3". Other areas show
blank. After 10 seconds will go into ready mode, and can
restart.
Possible Reasons:Over the rated load cause too much
electricity that make system Self-preservation or some
parts blocked and make DC motor can't process. Adjust
the machine and restart. Another please check the DC
motor or controller have any burned smell or not. If yes,
please change the motor or controller. Another make
sure the power and voltage is comply with standard.
Check incline motor sense wire and AC wire are inserted
well; AC wire is right inserted according to the indentify
in the incline motor; make sure the incline motor wire
without damager; after check those, press the button on
controller, then start self-learning again.
Check incline motor sense wire and AC wire are inserted
well; AC wire is right inserted according to the indentify
in the incline motor; make sure the incline motor wire
without damager; after check those, press the button on
controller, then start self-learning again.
Stop and go into fault status, computer buzzle will ring 3
tones and shows fault code"E6". Other areas show
blank. If recover then go into ready mode, then can
restart.
Possible Reasons:The power voltage is less than
normal or the controller has some problems. Make sure
the motor wire is connecting well.
Change upper EEPROM