Technical Data

Flip over combination mitre / bench saw
Art. No
Service connection
Rated input
No-load speed
Saw blade dia. x hole dia
Saw blade thickness
Min. workpiece dimensions
Max. Cutting depth at
Mitre 0°/ Bevel 0°
Mitre 45°/ Bevel 0°
Mitre 0°/ Bevel 45°
Mitre 45°/ Bevel 45°
Inner diameter – suction nozzles
Weight
Noise details
Sound pressure level L
pA
Sound power level L
WA
Measured according to EN 61029; Uncertainty K = 3 dB (A)
Wear ear protectors!
Read and understand the operating
instructions before using the
appliance. Familiarise with the
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
Persons over 16 years of age can only work on the
appliance. An exception includes youngsters trained
in order to reach knowledge under supervision
of the trainer during occupational education.
In case of any doubts about connection and operati-
on refer please to our customer center

Specified Conditions Of Use

The saw is intended solely for sawing profiled timber
within the cutting performances specified in the
technical data.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
It is strictly prohibited to disassemble, modify
and purposely remove the protective equipment on
the unit and fit other protective equipment instead.
TKGS 216
55254
220-240 V~50Hz
1800 W
5000 min
-1
216 mm x 30mm 24 Z 254 mm x 30 mm 48 Z
2,4 mm
200 x 10 mm
85x32 / 55x32 mm
85x50 mm
120x32 mm
120x50 mm
35 mm
10,5 kg
99 dB (A)
110 dB (A)
Even when the device is used properly and all safety
regulations are complied with, there still may be
some residual risks.
• noise emissions
• dust emissions
• vibrations to hand and arms
• Danger of burns
Tool and workpiece heat up during operation.
• Risk of injury
Sharp tools and workpiece edges

Emergency procedure

Conduct a first-aid procedure adequate to the injury
and summon qualified medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. If you seek help, state the
following pieces of information: 1. Accident site, 2.
Accident type, 3. Number of injured persons, 4. Injury
type(s)
ENGLISH
TKGS 254
55256
220-240 V ~50Hz
2000 W
4500 min
-1
2,4 mm
200 x 10 mm
90x45 / 55x45 mm
90x70 mm
130x45 mm
130x70 mm
35 mm
13,5 kg
99 dB (A)
110 dB (A)
31