Tests
– Press
NOTICE
Damage to the probe connector
The probe connector may be damaged if it is not installed correctly in WABCO Leakage Finder 2.0.
– Install the desired probe at the specified position (slot for the probes has a notch).
Ö The connector engages noticeably in the slot.
Ö The probe is now ready for operation.
– Connect the airborne sound probe to the WABCO Leakage Finder 2.0.
The flexible airborne sound probe is used in areas that are difficult to access. With the 30 cm long
special probe, parts of the system that are difficult to reach can be tested much more easily.
Using the headphones:
– Connect the connecting cable to the headphones and the WABCO Leakage Finder 2.0.
When connecting the headphones, make sure that both connectors (on the WABCO Leakage Finder
2.0 and on the headphones) are fully plugged into the jack socket.
– Put on the headphones.
Alternatively, the loudspeaker can be used.
The loudspeaker must be charged via a separate USB cable before it is put into operation.
A red LED lights up during charging. This goes out when the charging process is finished.
Please also refer to the supplied operating instructions.
– Plug the speaker's jack into the jack socket of the WABCO Leakage Finder 2.0.
– Activate the speaker by pressing the button on the back until the blue light is activated.
To detect leaks, swivel the probe right, left, up or down.
– Follow the acoustic and visual signals to determine the leakage.
Ö An increasingly louder sound and an increasing level on the display indicate an ultrasonic source
and thus also a leakage.
– Adjust the volume using the arrow buttons
experience.
Ultrasound reflects on surrounding walls and objects. Therefore, make sure that you have
located the leakage and not an opposite reflection.
NOTICE
Damage to the probe connector
The probe connector may be damaged if turned while disconnecting it from the WABCO Leakage
Finder 2.0.
– Press the button to release the connector.
– Pull the probe out of the slot straight and carefully.
to turn on the WABCO Leakage Finder 2.0.