Herunterladen Inhalt Inhalt Diese Seite drucken

Mount The Knob Socket; Mount The Retrofit Kit 1 (Without Fans); Mount The Retrofit Kit 2 (One Fan) - Truma S 3004 Gebrauchsanweisung Und Einbauanweisung

Vorschau ausblenden Andere Handbücher für S 3004:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Mount the knob socket

– Push the knob socket (4) with the cable from the operating
side through the cover (11) and click into place.

Mount the retrofit kit 1 (without fans)

– Connect the cable on the knob socket (4) to the sensor PCB (2).
– Close all unused openings with a blank cover (12).
– Push the cable into the clamp on the cover.
12 V connection
A12 V power supply is required to operate the lighting (alter-
nating current ripple < 1.2 Vss).
– Disconnect the fuse holder from the 12 V-cable (7).
– Thread the 12 V cable through the opening in the support
(10) and place over the installation box.
– Connect the fuse holder to the cable again.
– Attach the fuse holder to a suitable point in the installation
space (min. 10 cm from the installation box) using the sup-
plied screws (8).
– Connect the cable on the sensor PCB (2) to any point.
– Do not attach the cable to the heater (hot surfaces).
12
11
4
2
11
4
2
– Connect the cable (7) to the onboard power system.
7

Mount the retrofit kit 2 (one fan)

– Connect the cable on the knob socket (4) to the sensor PCB (2).
– Push the integrated control panel (5) from the operating
side through the cover (11) and click into place.
– Connect the cable (6) on the control panel (5) and the sen-
sor PCB (2).
– Close all unused openings with a blank cover (12).
– Push the cable into the clamp on the cover.
– Connect the cable (14 – fan).
Cabling
Integrated control panel is fitted on the left
5
6
14
2
10
2
11
4
11
4