Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; Explanation Of Symbols; Conditions For Use - Dräger X-plore 4740 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für X-plore 4740:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Strictly follow the Instructions for Use
Any use of the half mask and respiratory filter requires full understanding
and strict observation of these instructions as well as the Instructions for
Use of the used respiratory filter. The half mask and respiratory filter are
only to be used for the purpose specified here.

Intended Use

The Dräger X-plore 4740 half mask can be used with a respiratory filter as a
filter apparatus set that protects against harmful gases, vapours and
particles. The choice of respiratory filter depends on the pollutants in the
environment.
The half mask can also be used as a breathing connection for purifying
respirators and hose breathing apparatus.
Marking
Manufacturer/product name
Filter connection
Mask body material
Size
Head straps
Harness
or:
Headband
Adaptor for headband
Components not marked
Inhalation valve disc
Button of inhalation valve
Exhalation valve disc
What is What? (A1/A2)
1 Mask body
4 Head straps
2 Inhalation valve disc 5 Harness
3 Exhalation valve disc 6 Adaptor
8
Dräger/X-plore 4740/CE mark/
EN 140:1998
RA = knuckle thread Rd 40x1/7"
SI = silicone
TPE = thermoplastic elastomer
SM = small-medium/ML = medium-large
R 55 224
R 53 303
RM 06 709
R 56 680
R 53 309
R 26 646
RM 05 064
7 Headband
8 Adaptor for headband

Explanation of Symbols

Caution! Strictly follow the Instructions for Use.
Respiratory protection against gases and vapours
Respiratory protection against dusts and particles
Respiratory protection during the spraying of paint,
disinfectants and other aerosols
Respiratory protection during the distribution of pesticides and
insecticides
Respiratory protection during painting and finishing
Respiratory protection during grinding, sawing and
cutting processes
Respiratory protection during welding and soldering

Conditions for Use

— The oxygen content of the ambient air must not drop below the following
limit values:
17 vol. % in Europe except for the Netherlands, Belgium, UK
19 vol. % in the Netherlands, Belgium, UK, Australia, New Zealand.
For other countries observe the national regulations!
— Never enter unventilated tanks, pits, canals, etc. when wearing filter
equipment.
— The types of the contaminants must be known.
— Make sure to wear the required protection for eyes and head.
— Select a suitable respiratory filter. The weight of the respiratory filter
must not exceed 300 g. Strictly follow the Instructions for Use of the
respiratory filter!

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis