Herunterladen Inhalt Inhalt Diese Seite drucken

Remedy Of Faults - Oase FiltoMatic CWS 7000 Gebrauchsanleitung

Teichfilter
Vorschau ausblenden Andere Handbücher für FiltoMatic CWS 7000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
9

Remedy of faults

Malfunction
The controller does not switch on
Water from the DN70 outlet does not return
to the pond
Dirty water pump does not switch on
UVC lamp does not switch on
Cause
No mains voltage
Controller incorrectly positioned on the UVC
clarifying unit
Aquamax pump not switched on
Stop valve closed with the lid open
Pump rotor blocked
Container already empty
Container partly emptied, dirty water pump
cannot prime
The cleaning programs are inactive at water
temperatures between0 °C and >35 °C
The dirty water pump has reached its max.
running time. The display shows "PS".
UVC lamp defective
The safety system in the UVC clarifying unit
has tripped as a result of overvoltage in the
mains
Remedy
Check mains voltage
Check supply lines
Check the controller seating
Switch on Aquamax pump
Open stop valve
Clean pump rotor
Fill container
Fill container
Now the dirty water pump can only be
operated manually.
Keep the PUMP key pressed for complete
drainage.
Wait for 1.5 hours. Once this time has
elapsed, the dirty water pump is operational
again.
Changing the UVC lamp
Switch of the mains voltage and on again to
reset the safety system
Check that the UVC lamp is lit in the
control window (blue light)
To test, we suggest to switch on the UVC
lamp using the UVC key (operating status
ON)
- EN -
31

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Filtomatic cws 14000Filtomatic cws 25000

Inhaltsverzeichnis