Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Information; Hazards Encountered By The Combination Of Water And Electricity; Correct Electrical Installation; Safe Operation - Oase FiltoMatic CWS 7000 Gebrauchsanleitung

Teichfilter
Vorschau ausblenden Andere Handbücher für FiltoMatic CWS 7000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
4

Safety information

Hazards to persons and assets may emanate from this unit if it is used in an improper manner or not in
accordance with its intended use, or if the safety instructions are ignored.
This unit can be used by children from the age of 8 and by persons with physical, sensory
or mental impairments or lack of experience and knowledge, as long as they are
supervised or instructed on how to use the unit safely and are able to understand the
potential hazards. Do not allow children to play with the unit. Do not allow children to
clean or maintain the unit without close supervision.
4.1

Hazards encountered by the combination of water and electricity

The combination of water and electricity can lead to death or severe injury from electrocution, if the
unit is incorrectly connected or misused.
Prior to reaching into the water, always switch off the mains voltage to all units used in the water.
4.2

Correct electrical installation

For your own safety, consult a qualified electrician when you have questions or encounter problems.
Electrical installations at garden ponds must meet the international and national regulations valid for
installers. Especially adhere to DIN VDE 0100 and DIN VDE 0702.
Compare the electrical data of the power supply with those indicated on the type plate on the UVC
clarifying unit.
Only operate the FiltoMatic CWS when plugged into a correctly fitted socket.
Please note that the power supply must be fused via a fault current protection system with a maximum
reference fault current of 30 mA.
Install the FiltoMatic CWS such that any risk of injury to persons is excluded.
Only use cables that are uncoiled.
Extension cables must be approved for outdoor use and meet DIN VDE 0620 standards.
Route the connection cable so that damage is excluded.
Keep all connection points dry. Risk of electrocution.
4.3

Safe operation

Only operate the FiltoMatic CWS if no persons are in the water.
Never carry or pull the UVC clarifying unit and the dirty water pump of the FiltoMatic CWS by holding
on the connection cables.
Do not operate defective units. Do not operate the FiltoMatic CWS if the electrical connection cables
are defective. Pull the power plug immediately. The connection cables of the UVC clarifying unit and
of the dirty water pump cannot be repaired. Replace the components. Dispose of the defective
components in compliance with the environmental regulations.
Never open the housing of the UVC clarifying unit, dirty water pump, control system or their attendant
components, unless this is explicitly mentioned in these instructions of use.
Only use original spare parts and accessories.
Never use the system for filtering fluids other than water.
The radiation of the UVC lamp, even in small doses, is dangerous for eyes and skin. Never operate
the UVC lamp in a defective housing or outside of the housing.
Never operate the UVC lamp without cleaning rotor, as this also acts as an eye protection against
UVC radiation.
Overvoltage in the mains could lead to operating malfunctions of the unit. For information, please refer
to chapter "Remedy of faults".
24

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Filtomatic cws 14000Filtomatic cws 25000

Inhaltsverzeichnis