Fig. 10-9
Characteristic of the pressure sensor (DS)
Item
Designation
P
Water pressure
U
Voltage
Tab. 10-20 Legend for
Fig. 10-9
10.3

Tightening torque

Component
Temperature sensor
Hydraulic line connections (water)
Gas line connections (refrigerant)
Fluid line connections (refrigerant)
Fluid line connections (refrigerant)
Backup heater
Tab. 10-22 Tightening torque
10.4
Minimum floor area and ventilation
openings
CAUTION
The use of refrigerant lines that have already been used
can lead to damage to the unit.
▪ Do not reuse a refrigerant line that has been used with
another refrigerant. Replace or carefully clean the refri-
gerant line.
▪ If the total refrigerant charge in the system is < 1.84 kg, there are
no further requirements.
▪ f the total refrigerant charge in the system is ≥ 1.84 kg, other min-
imum floor space requirements must be met:
1
Compare the total refrigerant charge in the system (m
maximum refrigerant filling (m
room (A
), (see ).
room
▪ If m
≤ m
: The device can be installed in this room without
c
max
any further requirements.
▪ If m
> m
: Proceed with the following steps.
c
max
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1444099_00 – 07/2018 – EN
Thread size Tighten-
ing
torque in
Nm
all
Max. 10
1''
25 – 30
5/8"
63 – 75
1/4"
15 – 17
3/8"
33 – 40
1.5"
Max. 10
(handtight
)
) with the
c
) permitted for the installation
max
10.2.2

Characteristic curves for pumps

800
700
100%
600
75%
500
400
50%
300
200
100
0
0
200
400
600
800
1000
m / L/h
H
Fig. 10-10 Residual head of the internal heating circulation pump
with heating support heat exchanger
Item
Designation
ΔP
Residual head of internal heating circulation pump
R
m
Flow rate of heating system
H
Tab. 10-21 Legend for
Fig. 10-10
2
Compare the minimum floor area (A
of the installation room (A
room
▪ If A
≤ A
+ A
: Proceed with the following steps.
min
room
room2
▪ If A
> A
+ A
: Contact your local dealer.
min
room
room2
3
Calculate coolant quantity (dm) exceeding m
4
Calculate the minimum opening range (VA
tion between the installation room and the adjacent room (see ).
5
The device can be installed if:
2 ventilation openings are provided between the installation
room and adjacent room (1 each at top and bottom)
Bottom opening: The bottom opening must meet the require-
ments for the minimum opening range (VA
close to the ground as possible. If the ventilation opening
starts on the floor, the height ≥ must be 20 mm. The bottom
of the opening must be ≤ 100 mm above the floor. At least
50% of the required opening area must be < 200 mm from
the floor. The entire area of the opening must be < 300 mm
from the floor.
Upper opening: The area of the upper opening must be lar-
ger or the same size as the lower opening. The bottom of
the upper opening must be at least 1.5 m above the top
edge of the lower opening.
Ventilation openings to the outside are not considered suit-
able ventilation openings.
2
A
(m
)
Maximum refrigerant filling permitted in a
room
28
29
30
31
Tab. 10-23 Maximum refrigerant filling permitted in a room
m
(kg)
Minimum floor area A
c
1.84
1.86
1.88
1.90
Tab. 10-24 Minimum floor area of indoor unit
10
Technical data
1200
1400
1600
1800
2000
) from with the floor area
min
) and the adjacent room (A
).
room2
: dm = m
 – m
max
c
) for natural ventila-
min
). It must be as
min
room (m
) (kg)
max
1,814
1,846
1,877
1,909
(m²)
min
28.81
29.44
30.08
30.72
Installation and maintenance instructions