Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
• Cloning of master transmitter (rolling code)

LED INDICATORS:

POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
Lit:
START
- START input activated
- Radio receiver 1st channel activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
Unlit: PHOT photocell input activated
PHOT
Flashing: no photocell connected.
Unlit: SWC input activated
SWC
Lit: closing limit switch is disengaged
Unlit: SWO input activated
SWO
Lit: opening limit switch is disengaged
Unlit: no error
ER
Lit: error in safety device test or anti-crush safety device tripped
Flashing: Thermal overload protection tripped
TABLE "A" - PARAMETERS
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGICS
DIP
Logic
Photocells during
1
opening
Block pulses during
2
opening
3
3-step logic
Transmitter
4
programming
5
Reversing motion
6
Not used
INSTALLATION MANUAL
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the autoset
cycle (and subsequently updated), before an obstacle alarm is generated.
0
99
WARNING: It affects impact force directly: make sure that current safety requirements are met with
the set value (*). Install anti-crush safety devices where necessary.
Cross out
Default
setting
Description
used
In the event beam is broken, photocell operation is disabled during opening. During closing, movement
ON
is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and closing. When beam is broken
OFF
during closing, movement is reversed only once the photocell is cleared.
ON
The start pulse has no effect during opening.
OFF
OFF
The start pulse has effect during opening.
ON
Switches to 3-step logic;
during closing, start reverses movement.
OFF
OFF
Switches to 4-step logic.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
ON
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
OFF
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters.
OFF
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
ON
Change this parameter if the opening direction needs to be changed (Fig.H).
OFF
Standard operating mode (Fig.H).
OFF
Unlit: motors Stopped (Off )
MOTOR
Lit: motors Moving (On)
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
RADIO
hidden key.
(VERDE)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset or search for mechanical stop in progress
SET
Fast flashing: Autoset failed
Flashing in sync with Radio LED: Transmitter deletion in progress
14) CONNECTION DIAGRAM FOR SEVERAL PAIRS (MAX. 4) OF A-CELLULA
FLX PHOTOCELLS FIG. L
15) ADJUSTMENT PROCEDURE
-
Before turning the unit on, check electrical connections.
-
Set the following parameters: Automatic Closing Time, motor force.
-
Set the logics.
-
Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations).
Description
CLOSED
DURING CLOSING
OPEN
DURING OPENING
AFTER STOP
3 step
4 step
opens
opens
stop
closes
closes
stop + TCA
stop + TCA
opens
opens
11