6.4.2 Dismantling, replacing and remounting the blade
WARNING!
Always wear work gloves when handling the blade.
WARNING!
Damaged or bent blades must always be replaced; never try to repair them! ALWAYS USE MANUFAC-
TURER'S GENUINE REPLACEMENT BLADES BEARING THE
1. Dismantle
To dismantle the blade (2), hold it firmly and unscrew both nuts
(1).
1
EN
30
2
SYMBOL! Make sure the blade is correctly balanced.
2. Reassembling
Tighten both fixing nuts (1) using a torque wrench set to 60-65
Nm.
WARNING!
If necessary, replace nuts and bolts
only with GENUINE SPARE PARTS.
1
2