Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Supply; Safety Instructions; Assembly - AL-KO JET 3500 INOX Classic Betriebsanleitung

Vorschau ausblenden Andere Handbücher für JET 3500 INOX Classic:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
Any other use shall be regarded as misuse.
Possible misuse
The garden pump must not be used continuously.
They are not suitable for conveying:
Drinking water
Salt water
Waste water
Foodstuffs
aggressive media, chemicals
corrosive, flammable, explosive or fuming
fluids
Fluids that are hotter than 35 °C
water containing sand and abrasive fluids.

SCOPE OF SUPPLY

Thermal protection
The equipment is fitted with a thermal protection
switch which switches the motor off in the event
of overheating. After a cooling-down phase of ap-
prox. 15 - 20 minutes the pump switches on auto-
matically.

SAFETY INSTRUCTIONS

CAUTION!
Danger of injury!
Only use the machine and the extension
cable if it is in perfect technical condition!
Damaged units must not be used.
Safety and protective devices must not
be deactivated!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
12
Electrical safety
CAUTION!
Danger when touching voltage con-
ducting parts!
Disconnect the plug from the mains if the
extension cable is damaged or severed!
We recommend connecting a RCD (re-
sidual current operated device) having a
nominal residual current of < 30 mA.
The house mains voltage must agree with the
details quoted in the technical data, do not
use any other supply voltage.
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
. Cable drums should always be unrolled
2
completely.
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.

ASSEMBLY

Setting up the equipment
1. Prepare a flat and solid location.
2. Erect the unit horizontally and safe from the
risk of flooding.
The unit must be protected from the rain
and direct water jets.
Connect the suction line
1. Select the length of the suction line (Fig. B
-16) so that the pump cannot run dry. The suc-
tion line must always be at least 30 cm under
the surface of the water.
2. Connect the suction line. In doing so, make
sure that the seal is leak-tight without dama-
ging the thread.
We recommend fitting flexible lines at the
pump inlet (Fig. A -1). This ensures that
mechanical pressure or tension cannot
be exerted on the pump.
JET3000 / JET3500 (INOX)
Instructions for use

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Jet 3000 classic

Inhaltsverzeichnis