Charcoal filter (filter version only)

Fig. 3
It absorbs unpleasant odours caused by cooking.
The charcoal filter can be washed once every two months (or
when the filter saturation indication system – if envisaged on
the model in possession – indicates this necessity) using hot
water and a suitable detergent, or in a dishwasher at 65°C (if
the dishwasher is used, select the full cycle function and leave
dishes out).
Eliminate excess water without damaging the filter, then put it
in the oven for 10 minutes at 100° C to dry completely.
Replace the mattress every 3 years and when the cloth is
damaged.
Assembly
Place the mat around the grease filter and fix it in place using
the devices provided.
Position the upper cap and fix it in place using the fixing pin.
To disassemble, perform the steps in the reverse order.

Replacing lamps

Fig. 4
Disconnect the appliance from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Replace the old light bulb with the one of the same type as
specified in the feature label or near the light lamp on the
hood.
1.
Using a flat head screwdriver or equivalent tool, carefully
pry loose the light cover.
2.
Remove the damaged light and replace with a new 12
Volt, 20 Watt (Maximum) halogen light made for a G-4
base SUITABLE FOR USE IN OPEN LUMINAIRES.
Follow package directions and do not touch new light
with bare hands.
3.
Reinstall the light cover. (it will snap shut).
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.