Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Installation - Oase Aquamax Eco 8000 CWS Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Aquamax Eco 8000 CWS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- GB -
Pos: 35 /Alle Produkte/CE-Herstellererklärung Pumpen @ 6\mod_1194858915864_121.doc @ 40237
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (2004/108/EC) as well as the low voltage direc-
tive (2006/95/EC). The following harmonised standards apply:
Pos: 36 /Pumpen/Schlammsauger/Alle Pumpen/Schlammsauger/EN-Normen Pumpen/Schlammsauger @ 0\mod_1126880686869_0.doc @ 5718
EN 60335-1, EN 60335-2-41, EN 55014-2, EN 61000-3-2, EN 61000-3-3
Pos: 37 /Alle Produkte/Unterschrift Hanke @ 0\mod_1126881079296_121.doc @ 5743
Signature:
Pos: 38 /Alle Produkte/Sicherheit/SIC Sicherheitshinweise Einleitung @ 7\mod_1205310799730_121.doc @ 45453
The company OASE has built this unit according to the state of the art and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accor-
dance with its intended use, or if the safety instructions are ignored.
Pos: 39 /Alle Produkte/Sicherheit/SIC Kinder und Jugendliche unter 16 Jahren @ 6\mod_1196356502951_121.doc @ 41194
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognise
possible danger or who are not familiar with these operating instructions, are not permitted to use the unit.
Pos: 40 /Pumpen/Schlammsauger/Aquamax ECO/Die Kombination von Wasser und Elektrizität Aquamax ECO @ 0\mod_1126270203223_121.doc @ 3937
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected or
misused. Only operate the unit if no persons are in the water! Prior to reaching into the water, always disconnect the
power supply to all units used in the water. Compare the electrical values of the power supply with those on the type
plate on the packaging or on the unit itself. Ensure that the unit is fused for a rated residual current of max. 30 mA via a
residual current-operating system. Only operate the unit when plugged into a correctly fitted socket. Keep the power
plug and all connection points dry! Protect the connection cable when burying to avoid damage. Only use cables,
equipment, adapters, extension or connection cables with an earthed contact and approved for outside use. Do not
carry or pull the unit by the connection cable! Never operate the unit if the cable or housing are defective! The power
connection cable of this unit cannot be replaced. If the cable is damaged, the entire unit has to be disposed of. Electri-
cal installations at garden ponds must meet the international and national regulations valid for installers. Never open
the unit housing or its attendant components, unless this is explicitly mentioned in the operating instructions. Never
carry out technical changes to the unit. Only use original spare parts and accessories. Only allow authorised customer
service outlets to perform repairs. Never run the unit without water! Never use the pump for fluids other than water! For
your own safety, consult a qualified electrician if you have questions or encounter problems!
Pos: 41 /Pumpen/Schlammsauger/Aquamax ECO/Elektrischer Anschluss Aquamax ECO @ 0\mod_1126270337051_121.doc @ 3961

Electrical connection

Only entrust an authorised expert to carry out the electrical connection in accordance with the German EVU and VDE.
VDE 0100 Part 702 is valid for all installations. Refer to the type plate for all capacity parameters. Only perform any
work on the unit when isolated!
Pos: 42 /Pumpen/Schlammsauger/Aquamax ECO CWS/Inbetriebnahme Aquamax Eco CWS @ 8\mod_1218634449016_121.doc @ 49685
Start-up
Attention! Never operate the unit without water flowing through!
The unit switches on automatically when connected to power. The pump will shut down after 10 attempts if the rotor is
blocked or runs dry. Disconnect the power supply and "flood the pump with water", or remove the obstacle. Following
this, the unit can be restarted.
Pos: 43 /Pumpen/Schlammsauger/Aquamax ECO R/Montage Aquamax ECO R @ 8\mod_1221034064546_121.doc @ 52183

Installation

Disconnect the power supply, then secure the unit to prevent unintentional switching on. Only use the unit in its hori-
zontal position and ensure stable installation on a firm ground. The unit must be positioned below the water surface
level and can be placed in (submerged) or outside of the pond (dry).
Dry installation (E)
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Open the strainer casings, remove the pump, remove the controller (3) as well as the suction adapter (2), and fit the
suction and pressure line. The installation accessories (4) in the form of stepped hose connection, seals and hose
clips are part of the kit.
Connection to the water filter (B)
Plug the union nut over the stepped hose connection, fasten hose (1" - 1 1/2") on the stepped hose connection and, if
necessary, fasten with the hose clip, plug stepped hose connection into the pump outlet, tighten the union nut, then
connect the other end of the hose to the water filter.
Connection to the satellite filter (C) or skimmer (D)
Plug the union nut over the stepped hose connection, fasten the hose to the satellite filter on the stepped hose connec-
tion, insert the latter into the inlet regulator of the strainer casing, then fasten union nut.
Attention! If you operate the pump in the strainer casing when submerged, ensure that the satellite filter or skim-
mer is always connected to the inlet regulator or that the inlet regulator is completely closed („0" position)!
The power supply must be disconnected to switch off the unit.
Pos: 44 /Pumpen/Schlammsauger/Aquamax ECO/Reinigung Aquamax ECO @ 0\mod_1126270761551_121.doc @ 4033
Cleaning
Attention! Always disconnect the power supply prior to starting cleaning and maintenance work!
Remove the hoses from the unit. Press in the engagement points on both sides of the outlet opening to the water filter
and open the strainer casing, remove the pump from the strainer casing, remove the inlet regulator from its guide,
rotate the pump housing, then clean the impeller vanes using a brush.
Clean strainer casings, hose connections and inlet regulator using clear water and a brush. After cleaning, fit the unit in