Resetting the EIB 741:
Press the Reset button on the rear of the EIB 741 to reset it.
The EIB 741 has three different reset modes, which influence the firmware version used as well as the network settings:
Mode
User settings
Default setting with user's
network settings
Default setting with standard
network settings
Notes:
The user cannot change the default setting for the firmware or the standard network settings, not even by updating the firmware.
Performing a reset in one of the two default settings modes does not delete the most recent firmware update.
The boot mode is set by the length of time that the Reset button is pressed.
Condition
Power supply switched on, reset = 0 (button not pressed)
Firmware version loaded
Version of the most recent
firmware update
Default setting
Default setting
t
< 5 sec.
Reset
6 sec. < t
< 9 sec.
Reset
t
> 10 sec.
Reset
Network settings
User settings
User settings
Default settings
Reset mode
User settings
User settings
Default setting with user's network settings
Default setting with standard network settings
Used for
Resetting the EIB 741 (occurs for
each switch-on)
Faulty firmware update
Faulty network settings
33