X5 = Do not use!
External trigger inputs X31:
The EIB 741 supports four independent external inputs for the triggering of trigger events. Differential
inputs as per RS-485; 120-Ohm terminating resistors can be activated.
Connection to the EIB 741: 9-pin D-sub, male
View
Pin no.
1
6
2
7
3
8
4
9
5
Housing
External trigger outputs X32:
The EIB 741 supports four independent external outputs with individual assignment to internal trigger
sources. Differential outputs as per RS-485.
Connection to the EIB 741: 9-pin D-sub, female
View
Pin no.
1
6
2
7
3
8
4
9
5
Housing
Assignment
Trigger In 1+
Trigger In 1–
Trigger In 2+
Trigger In 2–
Trigger In 3+
Trigger In 3–
Trigger In 4+
Trigger In 4–
GND
Shield
Assignment
Trigger Out 1+
Trigger Out 1–
Trigger Out 2+
Trigger Out 2–
Trigger Out 3+
Trigger Out 3–
Trigger Out 4+
Trigger Out 4–
GND
Shield