SPARK PLUG

0.6 - 0.7mm
(0.024 - 0.028) in
BATTERY AND FUSES
+
A
RECOMMENDED BATTERY: YT14B-BS (YUASA)
The Spark Plug is located inside the left side panel above the passenger footboard.
Remove the carbon deposits from the spark plug with a small soft wire brush or a spark
plug cleaning machine. After cleaning (or replacing with new) re-adjust the Spark Plug gap
to the specified limit by using a Spark Plug gap thickness gauge. The Spark Plug should
be changed periodically.
When removing carbon deposits, observe the porcelain tip for signs if the Spark Plug is
suitable for your engine and type of riding. Under normal usage, the porcelain tip should
Access
be light brown or tan in colour.
to spark
If the porcelain tip is white or glazed, the spark plug has been operating too hot and your
plug
engine will require a "cooler" plug. Consult your ADIVA dealer for advice when selecting
another heat range.
Recommended Spark Plug: CR7E (NGK)
The Battery (12 Volt DC) is located under the rear section of the seat compartment. Your
AD3 uses a maintenance free battery which does not require top-up of battery fluid.
For maintenance, check the battery terminals (A) for any signs of corrosion. If corrosion is

FUSES

present, use a soft wire brush and clean rag to remove the contaminants then apply lightly
with
If you remove the battery, ensure that the polarity is correct when replacing the battery.
-
Red Cable indicates Positive terminal
Fuses are to the left of the Battery next to the negative terminal. Check for signs of
corrosion and replace if necessary. Ensure that the same rating is used when replacing
any fuses. Using wrong rating can cause electrical and electronic failure and even fire.
Caution:
Use only specifed Spark Plug or heat range for your engine.
Improper fit or heat range can severely damage your engine and
void the warranty
Dielectric grease
only.
Warning:
DO NOT open or puncture the battery casing! The contents are
highly corrosive and poisonous and can cause serious harm to
skin and lungs, even death. Use extreme care when disposing
the used battery, DO NOT place near or throw into flames