Herunterladen Inhalt Inhalt Diese Seite drucken

D) Configuration Of The Relay Function - Renkforce 754389 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

d) Configuration of the Relay Function

Relay function when entering a correct user code:
40
+ Time 1...999 seconds +
With this setting, the relay is activated for a specific time if the correct user code has
been entered. After the end of this time, the relay automatically shuts off and the code
lock is in standby mode again.
If the code lock is to activate a door opener, setting of a time between 1 and 5 seconds
is usually enough.
40
Example:
been entered
4
#
+
= Toggle
For every correct input of the user code, the relay switches to the respective other
position (on -> off -> on -> off.....).
42
#
+
= Toggle with quick input
If this function is selected, the relay can be switched on with the first two digits of the
user code and the button „
For deactivation of the relay, however, the complete code must be entered for
safety reasons.
Relay function when entering a correct code of the access lock:
50
+ Time 1...999 seconds +
With this setting, the access lock is activated for a specific time if the correct code
has been entered; the red LED lights up. After the end of this time, the access lock
automatically shuts off and the code lock is in standby mode again.
50
Example:
if the correct code has been entered
5
#
+
= Toggle
At every correct input of the code, the access lock is activated or deactivated.
44
#
= Activate relay for 1....999 seconds
5
#
+
+
= Activate relay for 5 seconds if the right user code has
#
".
#
= Activate access lock for 1....999 seconds
600
#
+
+
= Activate access lock for 600 seconds (10 minutes)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis