This product is only to be installed and used indoors in dry conditions.
By means of the tripod socket (10) on the top and bottom, the camera can be mounted
to a wall or ceiling using a suitable bracket (not included in the delivery).
Pay attention when tightening the bracket that no cables or pipes are damaged.
The camera should not be pointed directly at bright sources of light or the sun, since
the image will be overexposed. Avoid vibrations, dust and magnetic/electric fi elds at
the mounting location. Do not bend the connection cable.
Connection
• The video signal (PAL) is available at the BCN connector (3). Use an adapter, if you do
not have a BNC cable for this connection.
• The Schuko safety plug at the end of the mains cable (1) is to be connected to a proper
mains socket (230 V/AC, 50 Hz) with protective earth conductor. When power is avail-
able, the Power LED (4) lights up.
• Set the correct input channel at the display device to display the camera image.
• Afterwards, adjust the camera in a precise manner in order to be able to monitor the
desired image section.
Adjusting Zoom, Focusing the Image
• First unfasten the two fastening screws (8 and 9). Rotate them slightly counter-clock-
wise so that both lens rings can be rotated.
• Turn the front lens ring to the left or right to adjust the desired focal length.
Then focus the image with the rear lens ring.
• Afterwards, fasten the two lens rings again using the two fastening screws (8 and 9).
Other adjustment options
a) DIP switch
The following functions can be selected on the DIP switch (2):
• Switch "AES AI/MI": The "AES" switch position stands for "Automatic Electronic Shut-
ter" (electronic iris), the "AI/MI" switch position for the automatic iris (the latter is to
be adjusted for the auto-iris lens included in the delivery).
• Switch "BLC OFF": Here, the automatic back light compensation can be switched on
or off ("OFF").
b) Switch "VIDEO DR./DC DRIVE"
The switch (6) is used to choose whether the lens requires a video control signal (Set-
ting "VIDEO DR.") or a DC control signal (Setting "DC DRIVE").
With the lens provided the switch (6) is to be set to "DC DRIVE".
c) Control bush
The plug (11) of the auto iris lens must be plugged into the control bush (5). This lens
needs a DC control signal.
Video control signal
Connection
Signal
1
+12 V/DC
2
IRIS
3
No function
4
GND/--
d) Rotary knob for the adjustment of the lens iris
With the rotary knob (7) the lens iris (with DC lenses) can be adjusted. Use a suitable
screw driver and change the setting slowly until you have attained the desired lens iris
adjustment.
The home technology brand for the entire house. More information at www.sygonix.com
DC control signal
Connection
Signal
1
DAMP -
2
DAMP +
3
DRIVE +
4
DRIVE-
Cleaning
Occasionally, clean the camera from dust and dirt, especially the glass of the lens. For
this, use a clean, soft, dry cloth! Do not rub too hard, to avoid scratch marks on the
glass, this will cause deterioration in the image quality!
Tips and Notes
a) Using a different lens
• The camera provides the option to use a "C" or "CS" lens. Please pay attention that
the screw thread, or the part of the lens that is pointing inwards, in direction of the
sensor, is not too long. Otherwise, the sensor will be damaged.
With the hexagon key included in the delivery, the lens can be attached to the camera
using a small grub screw.
Do not touch the image sensor! Furthermore, ensure that no dust or soiling
enters the camera's interior! Never operate the camera without lens!
• To connect the control cables of the lens, observe the connector pin assignment for
the control bush in chapter "Other adjustment options".
b) General
• Install the camera so that it can not be reached without using auxiliary means.
The same applies to the connection cables. Ideally, they should be run in a plastic or
metal pipe.
• Increasing the cable lengths causes deterioration in the video signal. In this case,
use a suitable amplifi er.
Disposal
Dispose of the unserviceable product according to the relevant statutory
regulations!
Technical Data
Image sensor:
8.5 mm (1/3"), Sharp CCD
TV System:
PAL
TV lines:
540
Effective resolution:
752 x 582
1.0 Vpp, 75 Ω
Video output signal:
Video output:
BNC
Light sensitivity:
0.2 Lux (F1.2)
Focal length:
3.5 – 8 mm
Lens type:
Auto Iris, DC
White comparison:
Automatic (AWB)
Signal-to-noise ratio (S/N ratio): > 48 dB
Shutter speed:
1/50 ~ 1/110000 s
Operating voltage:
100 - 240 V/AC, 50-60 Hz
Input:
Max. approx. 2.3 W
Ambient temperature:
-10 to +50 °C
Dimensions (W x H x D):
65 x 47 x 172 mm
Weight:
Approx. 517 g
Legal notice
These operating instructions are a publication by Sygonix GmbH, Nordring 98a, 90409 Nürnberg (www.sygonix.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming, or the capture
in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is
prohibited. These operating instructions represent the technical status at the time of printing. Changes in techno-
logy and equipment reserved. © Copyright 2011 by Sygonix GmbH.
Nr. 43199D - Version 09/11

Werbung

loading