If the „housing back" (1) of the motion
detector is removed, a terminal strip is
visible.
• After a successful connection, set the motion detector onto the premounted cover and fasten
it with the fastening screws you removed earlier.
• Adjust the Motion Detector to the desired position.
• Replace the main fuse into your fuse box (in the case of screw locks/ automats) or switch on
the main fuse.
• When the motion detector is supplied with voltage, it takes about 60 seconds for initialisation.
Then the motion detector is ready-for-operation. As soon as motion is detected, the red LED
lights up (behind the diffuser lens).
Timer and Brightness Setup
The motion detector has a rotary knob for brightness
adjustment, (see Figure A on the right) (setting range
5 Lux to 1000 Lux) and a „rotary knob for timer set-
ting" (setting rage 10 seconds to max. 10 minutes).
Set the necessary brightness as well as the desired
working duration from the time of an instance of moti-
on detection.
A = Controls for timer setting
B = Controls for brightness setting

Maintenance and Cleaning

Apart from an occasional cleaning of the lens, this product is maintenance-free.
Please use a clean, lint-free, and dry antistatic cloth to clean the motion detector. Do not use
abrasive or chemical agents, or cleaners containing solvents. Do not press too hard on the dif-
fusion lens.
Disposal
Electrical and electronic products do not belong in the household waste!
Please dispose of the device, when it is no longer of use, according to the current sta-
tutory requirements.

Technical Data

Coverage:
Range:
Operating voltage:
Recommended installation height:
Resistive load:
Inductive load:
Protection type:
Dimensions:
Weight:
Operating temperature:
Connection explanation (from left):
L: Connect the phase of the electrical supply here
(230 V/AC 50 Hz).
N: Connect the neutral conductor of the electrical
supply here (230 V/AC 50 Hz).
N: Connection of neutral conductor of the consumer
load.
L: Connection of the phase of the consumer load.
Omic loads up to a maximum of 1000 watts and
inductive loads of up to a maximum of 500 watts can
be connected and switched.
horizontal 150°
max. 12 metres
230 V/AC 50 Hz
2.5 to 3 metres
max. 1000 Watt
max. 500 Watt
IP55
approx. 66 x 58 x 80 mm
approx. 170 grams
-20 to +50 °C
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.