Conrad 13 02 30 Bedienungsanleitung Seite 5

Vorschau ausblenden Andere Handbücher für 13 02 30:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Measuring range
Jumper JP2
200 mV
S
0
2 V
0
0
20 V
0
0
200 V
0
0
600 V
0
0
Where: "-" = not used; "0" = no jumper; "S" = jumper, i.e. two
pins bridged
g) When the required jumpers are "set", assemble the counter
module (insert measuring board, position housing shell,
screw in fixing screws, and tighten carefully).
h) After the panelmeter has been assembled, fix the previously
defined voltage range through a solder bridge. Observe the
labelled "tag block" on the rear of the panelmeter*. Proceed
as follows and observe the following table:
Measuring range
solder bridge
200 mV
no solder bridge necessary, al 8 soldering
points open
2 V
solder bridge on the two soldering points on
the extreme right, rest (6 soldering points)
open
20 V
solder bridge on the second soldering point
from the right, rest open
200 V
solder bridge on the third soldering point
from the right, rest open
600 V
solder bridge on the fourth soldering point
from the right, rest open
* Panelmeter viewed from behind
8
displayed unit
of measurement
S
-
-
-
mV
S
-
-
-
V
S
-
-
-
V
S
-
-
-
V
S
-
-
-
V
Attention!
Incorrect adjustment of the settings can lead to misreadings or
damage(s) to the panelmeter. In addition, danger to life may be
caused by touching supposedly low voltages.
5.2 Installation
The installation dimensions comply with DIN 43700, Type 2. The
panelmeter is supplied in partially disassembled condition. To
install, proceed as follows:
a) Mount the panelmeter in the housing or tableau or control
cabinet recess so that the display is legible. When the panel-
meter is fitted in the housing recess (not too much play/slip-
page), mount the
fixing bars (sliding guide) laterally onto
the panelmeter and secure each of the bars with a knurled
nut.
b) After fixing in the housing recess (tableau, control cabinet or
similar) connect the voltage-free supply cable with the cor-
rect polarity ("+" and "-" must be observed) to the panelme-
ter at "GND" = "-" and at "9V" = "+" (by soldering on).
c) Then connect the voltage-free instrument lead with the cor-
rect polarity (observe "+" and "-") at "COM" = "-" and at
"Vi" = "+" (likewise by soldering).
d) When the connections have been made, check the soldering
points ("cold" soldering points, cable partings, short-circuits
in adjacent strip conductors).
9