Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Technical Data; Cleaning And Maintenance - VOLTCRAFT PB-6 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATION

Check the battery level of the internal battery before each use. Fully charge
the internal battery before each use.
Ensure that the connection specifications for your mobile device comply
with the connection data for the product (see technical data). Always read the
operating instructions for your mobile device.
Do not short-circuit the USB outputs.
The charging cable is not suitable for data transfer.
a) Light
The product is equipped with an LED light.
• Press the on button (2) twice to turn on the LED light (3).
• Press the on button twice again to turn the light off.
b) Charging the power bank
Battery level indicator
The battery level indicator shows the current charging level of the internal battery. Each
charging level (30%, 70%, 100%) has an LED indicator.
Charge the internal battery when the 30% LED indicator is on or flashing.
Charging the internal battery when it is fully discharged takes about 8 hours.
If you only use the product occasionally, we recommend that you fully charge the
internal battery every three months in order to retain maximum capacity.
1. Connect the micro USB connector (8) on the charging cable (6) to the IN 5V charging port
(4).
2. Connect the USB-A connector (7) on the charging cable to a USB port on a computer or
another suitable USB power source.
3. The charging process commences.
» When the capacity of a particular charging level is reached, the LED indicator stays on.
The LED indicator flashes if the capacity has not been reached.
» The battery is fully charged when the 100% LED indicator stays on.
4. Disconnect the product from the USB power source as soon as the internal battery is fully
charged.
5. The product is ready for use.
c) Connecting and charging a mobile device
The product switches itself off automatically after approximately 30 seconds if it is
turned on and no mobile device is connected.
Overload protection
The product switches to the secure mode in the event of an overload. Disconnect the
mobile device immediately if this occurs. Charge the product to return it to its normal
mode.
1. Connect the mobile device using the charging cable. The adapters (9) can be easily
connected to the micro USB connector on the charging cable. No adapter is necessary for
mobile devices with a micro USB connection.
2. Connect the USB-A connector on the charging cable to the OUT 5V user connection port.
3. Press the on button. The charging process commences.
» Monitor the charging process.
» The battery level of the internal battery is shown on the LED indicators; the respective
charging level flashes.
4. Disconnect the charging cable from the product when the mobile device is fully charged.
The product turns itself off automatically after 30 seconds.

CLEANING AND MAINTENANCE

Never use any aggressive detergents, rubbing alcohol or other chemical
solutions as these can damage the charger housing or even impair the
charger's functionality.
• Disconnect the charging cable and connected devices from the product before cleaning.
• Do not immerse the product in water.
• Under no circumstances should you service any of the components in the interior of the
product, therefore never open/dismantle it.
• A dry, soft and clean cloth is sufficient for cleaning the product. Do not press too hard on the
charger housing as this can lead to scratch marks.
• Dust can be easily removed using a soft and clean long-haired brush.
DISPOSAL
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
The built-in battery must be removed by a specialist before disposal.
b) Batteries / Rechargeable batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries; disposal of them in the household waste is prohibited!
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that
disposal in the domestic waste is forbidden. The designations for the heavy metals
involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable)
batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

Input voltage / current ...................5 V/DC, max. 500 mA
Output voltage / current ................5 V/DC, max. 1000 mA
Internal rechargeable battery ........3.7 V/DC Lithium polymer (LiPo) / 3000 mAh
Operating conditions .....................-10 to +60 °C, ≤85 % RH (non-condensing)
Storage conditions ........................-10 to +45 °C, ≤75 % RH (non-condensing)
Dimensions (W x H x D) ...............94 x 15 x 54 mm
Weight ..........................................97 g
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2014 by Conrad Electronic SE
V2_1014_02_JH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis