Herunterladen Inhalt Inhalt Diese Seite drucken

Oase Filtoclear Gebrauchsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für Filtoclear:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Important! Only use lamps the designation and rating of which match the information on the type plate.
Remove the O ring from the quartz glass and clean, clean the quartz glass tube using a moist cloth, pull out the flat
sealing ring and the protection tube, clean with water.
Check components for damage and replace, if necessary. Reassemble in the reverse order. Start up the pump first,
then connect the unit power supply.
Note!
A safety switch prevents switching on the UVC lamp as long as the UVC water housing is removed.
Wear parts
The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the warranty.
Remedy of faults
Trouble shooting
Water does not clear
UVC lamp display is not
No water coming from the outlet − Pump power supply not connected
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the unit, check for damage. Remove, clean, dry and store all foam inserts in a
frost-free environment. Ensure that the storage place is inaccessible to children. Cover the filter container such that the
ingress of rain water is excluded. Drain all hoses, pipes and connections as far as possible.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Cause
− Unit has been in operation only for a short time
− Inadequate pump capacity
− Water extremely soiled
− Excessive fish and animal population
− Foam filters soiled
− Quartz glass tube soiled
− Power supply of Filtoclear-UVC not connected
− UVC lamp defective
− Connection defective
− UVC lamp capacity exhausted
− Protection tube not installed
− Filtoclear-UVC overheated
− Function switch turned to „Cleaning"
− Outlet blocked
Remedy
− The complete biological cleaning effect is only achieved
after several weeks
− Readjust the pump capacity
− Remove algae and leaves from the pond, perform a
partial water change
− Guide value: approx. 60 cm fish length per 1 m³ pondwa-
ter
− Clean foam filters
− Remove Filtoclear-UVC and clean quartz glass tube
− Connect power supply of Filtoclear-UVC
− Replace the UVC lamp
− Check electrical connection
− Replace the lamp after approx. 8,000 operating hours
− Refer to 'Replace UVC lamp'
− UVC automatically switches on when cooled down
− Turn function switch to „Filter"
− Connect pump power supply
− Clean outlet
- GB -
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis