c) Installation and assembly
• The outdoor sensor can be mounted on the wall through its rear opening using a nail, screw or hook.
A small fold-out base also allows installation on a level surface.
The outdoor sensor is suitable for use in protected outdoor areas. It should be placed so that it is not
exposed to direct sunlight, since this can result in a false temperature reading. Precipitation falling on the
outdoor sensor will also lead to a false temperature reading, since this cools the housing.
Therefore, we recommend choosing the installation place carefully, so the outdoor sensor measures the
correct temperature.
Never dip the outdoor sensor in or under water; this will destroy it!
• The base station can be mounted on the wall through its rear opening using a nail, screw or hook.
Using a fold-out base, the base station can be placed on a fl at, stable surface. Protect valuable furniture
surfaces by using a suitable mat to prevent scratches.
Manual Search for Outdoor Sensors
• Press and hold the "SEARCH" button for 3 seconds until a tone signal can be heard. Then the display for
the outdoor temperature and the reception symbol fl ash (top right of the display). The base station now
searches for the outdoor sensor for the time period of approx. 3 minutes.
Do not press any button during the sensor search.
• In case of reception problems, reduce the distance between the outdoor sensor and the base station or
select a different installation location.
Switching between temperature units °C/°F
• Briefl y press the button "F°C/°F" on the base station in order to toggle between the units of temperature
°C (degrees Celsius) and °F (degrees Fahrenheit).
Alarm functions
The base station provides the option to emit an alarm signal if the outdoor temperature falls below and/or
exceeds a limit value.
Switching alarm on/off
Briefl y press the "ALERT" (B7) button several times to switch between the following functions:
• Display "
": Alarm if the upper limit value is exceeded
• Display "
": Alarm if the temperature falls below the lower limit value
• Display "
": Both alarms activated
• No display: Both alarms deactivated
Setting limits
• Hold down the "ALERT" button for 3 seconds until a beep can be heard. Now both the symbol "
the upper limit value fl ash in the display (e.g. +70 °C).
• Set the upper limit value using the " S" or "F" button (in increments of 1 °C).
If the respective key is pressed for a longer period of time, quick adjustment is performed.
If you do not press any key for 15 seconds, the base station saves all settings and exits the
settings mode automatically.
• If you briefl y press the "ALERT" button, the lower limit value is shown in the display (e.g. -20 °C) and the
symbol "
" fl ashes.
• Set the lower limit value using the " S" or "F" button (in increments of 1 °C).
• If you briefl y press the "ALERT" button again, the device exits the settings mode and all settings will be
saved.
Stopping alarm signal
• If the upper limit is exceeded, then the base station emits an alarm signal for 2 minutes and the symbol
"
" fl ashes.
• If the lower limit is exceeded, then the base station emits an alarm signal for 2 minutes and the symbol
"
" fl ashes.
• The alarm can be terminated prematurely by pressing any button.
The corresponding symbol will stop fl ashing only when the outdoor temperature is within the set
limits again.
MIN/MAX values
The base station always displays the MIN/MAX values of the last 24 hours; manual deletion is not possible.
Low temperature alert
If the outdoor sensor measures a temperature between -2 °C and +3 °C, a symbol for the
frost warning appears to the left of the outdoor temperature; see image to the right.
Range
The transmission range of the radio signals between the outdoor sensor and the base station is up to 30 m
under optimum conditions.
This transmission range data refers to the so-called "free-fi eld range". However, this ideal
arrangement (e.g. base station and outdoor sensor on a plain, even meadow without trees,
houses etc.) never exists in practice.
Due to the different infl uences on the radio transmission, no specifi c range can be guaranteed. However,
trouble-free operation is usually possible in a single family house.
The range can be signifi cantly reduced by proximity to cables, pipes, metal pieces, electronic devices, and
similar. Thick walls, steel construction, laminated insulation glass windows, etc., also reduce the range very
signifi cantly.
If you notice that the base station does not contain any measured values of the outdoor sensor, check the
condition of the batteries in the outdoor sensor fi rst. Following that, select another location for the base sta-
tion and the outdoor sensor. If required, perform a manual search for the outdoor sensor (see the "Manual
search for the outdoor sensor" chapter).
Disposal
a) General instructions
Dispose of unserviceable products in accordance with the relevant statutory regulations.
b) Disposal of used batteries/rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all used batteries/rechargeable bat-
teries; disposal of them in the household waste is prohibited!
Batteries/rechargeable batteries that contain hazardous materials are labelled with the follow-
ing symbols to indicate that disposal in the household waste is forbidden. The symbols of the
relevant heavy metals are: Cd = Cadmium, Hg = Mercury, Pb = Lead.
You can return your used batteries/rechargeable batteries free of charge at the offi cial collection points of
your community, in our stores, or at places where batteries or rechargeable batteries are sold!
By doing this, you fulfi l your statutory obligations and contribute to the protection of the environment!
Declaration of Conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this product con-
forms to the fundamental requirements and the other relevant regulations of the directive 1999/5/EC.
The Declaration of Conformity (DOC) for this product can be found at www.conrad.com.
" and

Technical Data

a) Base station
Power supply ...............................2 batteries of type AAA/Micro
Temperature range ......................-10 °C to +50 °C
Resolution ............................0.1 °C
Accuracy ...............................±1 °C (in the range of 0 °C to +40 °C)
Dimensions ..................................136 x 82 x 16 mm (W x H x D)
Weight .........................................approx. 100 g
b) Outdoor sensor
Power supply ...............................2 batteries of type AAA/Micro
Transmission frequency...............433 MHz
Transmission range .....................up to 30 m (see chapter "Range")
Measurement interval ..................approx. 1 minute
Temperature range ......................-20 °C to +50 °C
Resolution ............................0.1 °C
Accuracy ...............................±1 °C (in the range of 0 °C to +40 °C)
Dimensions ..................................62 x 101 x 24 mm (W x H x D)
Weight .........................................approx. 60 g
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2013 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis