Isothermal function
The isothermal function can display de nable temperature ranges with the same colour scheme, similar
to a lter. This allows the particularly relevant temperature ranges to be made visible. Using speci c
parameters, the isothermal function must be set for each speci c measurement task. The settings
parameters resemble a "if-then" function. If the prede ned condition is met, the temperature range
is displayed as determined.
ISO
Settings
Clear Screen
ISO Setting
Mode:
Above
Level:
22.9 °C
Width:
1.1 °C
Color:
Green
!
To mask certain areas of the image, you can use the colour black in MIX mode (14.3)
to conceal the parts of the image you do not want to see.
17.1
Settings
Users can quickly and safely make complex adjustments to default settings which affect all relevant device
parameters. Special default settings make it easier to adjust the settings for speci c applications as they
can then be pre-con gured using the PC software.
ISO
Settings
Clear Screen
46
GB
ISO
Settings
Clear Screen
Mode
ISO Setting
Mode:
Unter
Target temperature in °C
Level:
22.9 °C
Temperature span
Width:
1.1 °C
Color:
Green
Color
Save settings
Example
Settings
Cancel
Remove Measures
Iron
Rainbow
ISO Setting
Mode:
Level:
Width:
Color:
Temperature "above",
"below" or "within"
in °C
Temperature range shown if
condition is met
Temperatures above target
temperature + show
temperature span in green
OK
Cancel
Remove Measures
Iron
Rainbow
Above
22.9 °C
1.1 °C
Green
Settings
OK