Herunterladen Inhalt Inhalt Diese Seite drucken

Using The Inverter; Status Indications - Dometic SINEPOWER MSI2324T Montage- Und Bedienungsanleitung

Sinus-wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
SinePower
10

Using the inverter

10.1
Switching on the inverter
➤ Set the main switch (fig. 5 3, page 4) of the inverter to the "ON" position.
Set the On/Off switch to "OFF" to switch off.
➤ The inverter performs a self-test.
During the self-test, the built-in speaker emits tones and the LED flashes.
✓ After the self-test is completed successfully, the LED lights up green (fig. 5 2,
page 4).
10.2

Status indications

The LED (fig. 5 2, page 4) shows the operating condition of the inverter.
Display
Green, constantly lit
Green, slow flash
Orange, quick flash
Orange, slow flash
Red, double flash
Red, quick flash
Red, slow flash
Red, constantly lit
Red, slow flash + double flash
The inverter switches off if:
• the battery voltage drops below 10 V (12 Vg connection) or 20 V (24 Vg
connection),
• the battery voltage exceeds 16 V (12 Vg connection) or 32 V (24 Vg
connection),
• the inverter overheats.
➤ If this happens, shut down the inverter with the main switch (fig. 5 3, page 4).
EN
Input voltage
Normal mode
Energy-saving mode
Input voltage too high
Input voltage too low
Inverter overheated
Overvoltage
Undervoltage
Overload
Fan fault
Using the inverter
23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis