Program description
Cleaning stop:
DIP-switch 5
Serves to disable the fitting prior to cleaning.
Dip-switch 5 ON = Cleaning stop
Dip-switch 5 OFF = Cleaning stop function disabled.
User detection
When you step in front of the
shower, the system will detect
The illuminating icon
you.
begins to pulse slowly.
30-70 cm
function enabled (default setting).
Enable cleaning stop
Approaching the hand to the
infrared sensor (see picture).
After 2 s the vertical line of the
ON/OFF icon begins flashing.
At the same time tap with the
second hand inside the ON/
OFF icon and the cleaning stop
is enabled.
The cleaning stop remains ena-
bled for 10 min after leaving
the sensor range.
ON
OFF
1 2 3 4 5 6
Disable cleaning stop
The function automatically
stops if no user was detected
for 10 minutes.
You can manually disable the
function following the same
procedure used to enable it.
The fitting will resume normal
operation with a safety delay
of 3 s after you leave the
sensor range.
WimTec OCEAN P7
Shower panel
EN
Warmlauf:
OFF
ON
6 5 4 3 2 1
Reinigungsstopp:
OFF
ON
6 5 4 3 2 1
Hygienespülung:
OFF
ON
6 5 4 3 2 1
Halbautomatik:
OFF
ON
6 5 4 3 2 1
Vollautomatik:
OFF
ON
6 5 4 3 2 1
Manuell:
OFF
ON
6 5 4 3 2 1