Configuring the programs & functions
Dip-switch:
Program activation - Dip-switch 1 and 2:
Program
Semi automatic program
Fully automatic program
Manual program
Function activation - Dip-switch 3 - 6:
Dip-switch
Function
3
Shut-off delay ON = 5 s / OFF
4
Warm water rinse
5
Cleaning stop
6
Stagnation rinse
Programs or functions are pre-adjusted fatory-made.
1)
Adjustable controller:
I.
Interval controller
for hygiene flushing
48 h pre-adjusted
(3 - 48 h adjustable).
If the shower control is not
used for the adjusted time the
armature releases a flushing
to rinse the pipes of stagnan-
cy water for 10 s by itself.
20
Shower panel
Dip 1
OFF
1)
ON
OFF
1)
1)
J.
Time controller
for security flushing stop
10 min pre-adjusted
(10 s - 10 min adjustable).
Manual program: 10 s - 60 s
After elapsing of adjusted
maximum flushing time the
shower control stops auto-
matically to save water at
an unintended permanent
activation.
WimTec OCEAN P7
Dip 2
Description
ON
Page 25
ON
Page 26
OFF
Page 27
Description
= 2 s
1)
Page 28
Page 29
Page 30
K.
Active range controller
for user detection
Active range 70 cm
pre-adjusted
(30 - 70 cm adjustable).
Delimits de active range of
the inrared sensor from
30 - 70 cm.
Automatic active range ad-
justment within the maximum
active range.