Herunterladen Inhalt Inhalt Diese Seite drucken

Cooper Hand Tools Weller WR 3M Betriebsanleitung Seite 38

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
14-20
Setting the vacuum OFF delay (VAC OFF)
To prevent the desoldering bit from becoming clogged, it is possible
to set a vacuum OFF delay of 0 to 5 s (factory setting 2 s).
1. Select the menu item VAC OFF in Menu 1.
2. Set the time value (VAC OFF) with the UP or DOWN button.
3. Proceed to the next menu item with the button ┌ 1 ┐ (back) or
┌ 2 ┐ (forward).
Setting the vacuum ON delay (VAC ON)
In order to prevent the pump from starting prematurely or to ensure a
defined soldering-joint preheating time, it is possible to set an ON
delay of 0 to 9 s (factory setting 0 s: Off).
1. Select the menu item VAC ON in Menu 1.
2. Set the time value (VAC ON) with the UP or DOWN button.
3. Proceed to the next menu item with the button ┌ 1 ┐ (back) or
┌ 2 ┐ (forward).
Switching the lock function ON/OFF
After the lock is switched on, only the temperature buttons ┌ 1 ┐,
┌ 2 ┐ and ┌ 3 ┐, Pick-Up and ┌ 1·2·3 ┐ can still be operated on the
repair station. All other settings are disabled until the repair station is
unlocked again.
To lock the repair station:
1. Select the menu item LOCK in Menu 1.
"OFF" appears in the display. The padlock symbol flashes.
Note
Pressing the buttons ┌ 1 ┐ or ┌ 2 ┐ while "OFF" is displayed results
in the menu item being exited without a stored lock code.
2. Set a 3-digit lock code with the UP or DOWN button.
3. Press button ┌ 3 ┐ for 5 seconds.
The code is stored. The padlock symbol is displayed. The station
is now locked. The display switches to the main menu.
To unlock the repair station:
1. Select the menu item LOCK in Menu 1.
"ON" appears in the display. The padlock symbol is displayed.
2. Enter the 3-digit lock code with the UP or DOWN button.
3. Press button ┌ 3 ┐.
The station is now unlocked. The display switches to the main
menu.
WR 3M

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis