Set-up location requirements

For safe and trouble-free operation of the appliance, the set-up location must fulfil
the following requirements:
The appliance may only be operated in a vertical position and fully assembled.
When using the feet, the device must be placed on a firm, flat and even floor.
When wall mounting, the appliance must only be mounted in a fixed position on
a vertical wall.
The minimum clearances between the housing and other objects must be main-
tained: 10 cm at the sides, 30 cm above, 15 cm below (with wall mounting) and
50 cm in front.
Ensure that air can always enter and escape freely. Otherwise, there could be a
heat build-up in the appliance.
Do not place the appliance in a hot, wet or extremely moist environment or in the
vicinity of flammable materials.
The mains power socket must be easily accessible so that the power cable can
be easily disconnected in an emergency.
Environmental temperature range: 0 to +40°C
Humidity (no condensation): 5–85%
DANGER
Fire risk due to contact with materials!
There is a risk of fire if the heating elements come into contact
with flammable materials!
Do not place the appliance in the vicinity of curtains and other flammable
materials.
Do not allow flammable materials (i.e. textiles) to come into contact with
the appliance.
Do not cover the appliance.
SKD 2300 B2
GB
29