SYSTEM SETTINGS (settings)
To access system settings, press the MODE button repeatedly until "Menu" appears in the top line of the display. Now select the menu item
"Menu Settings" using UP and DOWN and press ENTER. Select the desired sub-menu item using UP and DOWN once again, and confirm with
ENTER (see tables, note sub-menus). Now change the settings as required using UP and DOWN and confirm the changes with
ENTER.
Settings
Display
=
automatic display
shutdown
DMX Fail
=
operating status
when DMX signal
fault occurs
DimCurve
=
dimmer curve
DimResp
=
dimmer sensitivity
Menu
ENTER
Settings
UP/DOWN
Dimmer curves
linear
DMX value
Backlight ON
Backlight OFF
Hold
Blackout
Linear
Exp
Log
S-Curve
LED
Halogen
Settings
ENTER
Backlight
Display
UP/DOWN
ENTER
/
Settings
ENTER
DMX Fail
DMX Fail
UP/DOWN
ENTER
/
Settings
ENTER
DimCurve
DimCurve
Linear
UP/DOWN
ENTER
/
ENTER
Settings
DimResp
DimResp
UP/DOWN
ENTER
exponential
logarithmic
DMX value
DMX value
= permanently on
= display shuts down automatically after approx. 30 seconds
of inactivity
= last command is retained
= activates blackout
= light intensity increases linearly with DMX value
= light intensity can be finely adjusted at lower DMX values
and broadly adjusted at higher DMX values
= light intensity can be broadly adjusted at lower DMX values
and finely adjusted at higher DMX values
= light intensity can be finely adjusted at lower and higher
DMX values and broadly adjusted at medium DMX values
= lamp responds abruptly to changes in DMX value
= spotlight responds similarly to a halogen spotlight with soft
brightness changes
Backlight
/
ON
OFF
ENTER
DMX Fail
/
Hold
Blackout
ENTER
DimCurve
/
Exp
ENTER
DimResp
/
LED
Halogen
ENTER
S-curve
DMX value
DimCurve
DimCurve
/
/
Log
S-Curve
ENTER
ENTER