ENGLISH
Trouble
The machine does not work, LED
screen (E1 ) does not turns on
The machine does not work,
indicator light ( E11) is red
The machine does not forward or
back
Brush motor does not work,
indicator light does not turns on
Drive motor does not work
Vacuum system motor does not
work
The dirty water vacuuming is
insufficient
The solution flow is insufficient
The squeegee leaves marks on the
floor
Machine cannot brake
TROUBLESHOOTING
Possible Cause
The battery connector is disconnected
The batteries are completely discharged
The batteries are discharged
The PCB or key board is broken
Emergency-stop button (A15) does not
release
Seat limit switch is not activated.
Squeegee has not lifted in reverse, LED
screen (E1) display ERR-01
The PCB or key board is broken
The deck motor is overloaded
There are foreign materials preventing
the brush from rotating
Error indicator (E4) is lit
Drive motor is overloaded
The recovery tank is full, light (E2) is red
The vacuum motor is overloaded
The PCB or key board is broken
The recovery tank is full, light (E2) is red
The hose is disconnected from the
squeegee
Vacuum assembly is clogged
The squeegee is dirty, or the squeegee
blades are worn or damaged
The tank cover (A2) is not properly
closed, or the gasket is damaged
The solution filter (D3) is dirty,
The solution is empty, light (E10) is red
Water switch (D2) indicate "0"
The solution is dirty
There is debris under the squeegee blades
The squeegee blades are worn, chipped
or torn
Do not start the drive motor brake
16
USER MANUAL
Remedy
Connect.
Charge the batteries
Charge the batteries
Change the PCB or key board
Turn and release
Sit on the seat of machine
Before reversing, lift the squeegee
Change the PCB or key board
Use less aggressive brushes suitable
for the floor to be cleaned, reset the
breaker
Clean the brush hub
Refer to ERROR INFORMATION
Check the drive motor, reset the
breaker
Empty the recovery tank
Check the vacuum motor, reset the
breaker
Change the PCB or key board
Empty the recovery tank
Re-connect
Clean or check
Clean and check the squeegee
Close the cover properly or replace
the gasket
Clean the filter
Full in water
Open the water switch
Clean the solution
Remove the debris
Replace the blades
Brake bracket is choked