Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Temperature Limitation; Maintenance - HANSGROHE Raindance Montageanleitung

Vorschau ausblenden Andere Handbücher für Raindance:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
Pressure differences
The pressures of the cold and hot water connections must
be balanced.

Operation

The mixer is activated by lifting the lever handle.

Temperature limitation

The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing the
safety button.
Adjustment (see page 13)
Correction is necessary if the temperature measured at
the take off point differs from the temperature set on the
scale. To adjust temperature proceed as follows:
Turn the setting knob until water at a temperature of 38°
C comes out of the outlet. Loosen screw of setting knob.
Remove setting knob and turn to the 38° C position.
Attach setting knob again and tighten the screw.
Safety Function (see page 13)
The desired maximum temperature for example max.
42° C can be pre-set thanks to the safety function.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa (see page 15)
Handshower (5)
Handshower + body showers (1)
Body showers, 2 jets (3)
Body showers, 4 jets (2)
Body showers, 6 jets (4)
4
English
Flow heater
Applicable for flow heaters at min. 24 kW and 0,15 MPa
flow pressure before the Shower panel and a minimum
through flow of 7 l/minute. Only one consumer possible,
not two simultaneously.

Maintenance

The non return valves (21) must be checked regularly
according to DIN EN 1717 in accordance with national
or regional regulations (at least once a year).
At this time, please also check the filter (14) situated
on the MTC-ther-moelement (14). After assembling the
MTC-thermo-element, it is necessary to check the water
temperature at the take off point as described under the
headline „adjustment". Before the adjustment, please
check, if the warm water supply is activated and the
maximum temperature of the warm water is available at
the take off point.
To guarantee the smooth running of the thermostat, it is
necessary from time to time to turn the thermostat from
total hot to total cold.
Spare parts (see page 19)
1
2
3
4
5
max. 1 MPa
6
0,2 - 0,5 MPa
7
1,6 MPa
8
9
max. 80° C
10
65° C
11
12
13
14
16,0 l/min
15
23,0 l/min
16
12,6 l/min
17
16,8 l/min
18
21,6 l/min
19
20
21
handshower
support, assy
hose 1,60 m
upper cover
escutcheon
filter
body shower Normal spray
handle
handle for thermostat
flange
frontcover
sleeve
adapter for handle
thermostat cartridge
nut
cartridge on/off control
sealing set
connection hose
mounting set
hose connection angel
non return valve
28519000
97024000
28276000
97324000
97326000
97973000
28406000
10490000
38391000
97858000
97859000
95032000
97108000
94282000
96945000
96645000
95037000
95539000
96179000
25948000
97350000

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

27005000

Inhaltsverzeichnis