Fault
Appliance does not
respond when buttons
are pressed.
Temperature display,
Fig. 2/1, is not lit.
Thicker frost along
the upper edge of the
appliance.

Customer service

Please check your telephone book or the
customer service list for your nearest
customer service facility. When
contacting customer service, please
ALWAYS quote the product number
(E number) and production number
(FD number) of your appliance.
30
Possible cause
Button lock" function
is switched on.
Appliance has been
switched off.
Power failure; the fuse
has been switched off;
the mains plug has not
been inserted properly.
Defrost water stoppers
not fitted correctly.
Transportation protection
devices were not removed.
The chest freezer lid is
opened frequently.
Remedial action
Cancel button lock, see Fascia".
Connect mains plug.
Check whether the power is on,
check the fuses.
Correctly insert defrost water stoppers on
the base of the appliance and on the front
of the appliance.
Remove all four transportation protection
devices, Fig. 3 (see Installing the
appliance).
Do not open the lid unnecessarily.