Herunterladen Inhalt Inhalt Diese Seite drucken

Replacement Of Motor - Apv W+ Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

381434 ISS S 01.98
381327 ISS Q 11.95
Impeller
Pump body
Rear flange
Screw
Extension frame
Motor
Shaft
Screw
Motor
Keyway
Motor shaft
Balance hole
Pump shaft
Protective
sleeve
381328 ISS Q 11.95
381329 ISS Q 11.95
5
Maintenance
Fig. 9

5.3 Replacement of motor

The standard motor for the W+ pump has a front-mounted bearing. If
the motor is replaced, the new motor must also have a front-mounted
bearing. The motor bearing is enclosed and permanently lubricated.
Follow the instructions below when replacing the motor. For replace-
ment of bearings, see the motor supplier's service instructions.
Fig. 10
1.
Disconnect the pump from the power supply.
2.
Remove the pump body. See Fig. 9.
3.
Remove the impeller.
4.
Remove the motor shroud and, if possible, stand the pump on the
end surface of the motor. See Fig. 10.
5.
Undo the four bolts between the motor and extension frame and
remove them. See Fig. 10.
6.
Lift the back plate and extension frame, which are still bolted
together, up and off the shaft. See Fig. 10.
7.
See Fig. 11. Loosen the screws in the shaft and pull the shaft out,
then replace the motor.
Fig. 11
8.
See figure 12. Before mounting the new pump shaft, remove any
dirt and grease from the engine shaft and the sleeve coupling's
internal clamping surfaces. Mount the pump shaft loosely.
Position the balance hole above the keyway.
9.
Fit the protective plastic sleeve on the shaft.
Fig. 12
10. Press the back plate and extension frame down over the shaft.
11. Tighten the bolts.
12. Turn the pump back so it stands on its legs/console.
13. Fit the impeller.
Remember to use the proper tension:
M10: 45 Nm (33 lbf ft)
M14: 70 Nm (52 lbf ft)
M20: 200 Nm (148 lbf ft)
381331 ISS Q 11.95
11

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis