3. Proper use

The appliance is only for use as living space heating
in dry rooms.
The equipment may only be used for the tasks it is
designed to handle. Any other use is deemed to be a
case of misuse. The user/operator and not the
manufacturer will be liable for any damage or injuries
caused as a result thereof.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data:

Rated voltage:
Output:
2000 W (750 W / 1250 W / 2000 W)
Thermostat controller:
Protection class:
Mains lead:
Equipment dimensions without feet approx.:

5. Before starting the machine

5.1 Assembly
The equipment can be used indoors in a free
standing position or mounted on a wall. Maintain all
minimum distances. The equipment may only be
used when completely assembled and standing
vertically.
a) Free standing installation (Fig. 2)
Ensure that a minimum distance of 230 mm to the
sides and 450 mm to the top of the equipment are
maintained. Observe section 1 "Safety regulations".
Caution: To prevent damage when attaching the feet
to the heater, place the heater upside down on a soft
surface (e.g. a carpet).
When attaching the feet, make sure that they are
positioned on the correct sides of the equipment
(notch facing inwards) and are fastened with 2
screws (A).
b) Wall mounting (Fig. 3)
Caution: Make sure that there are no electric cables
or other installations (for example water pipes) near
12
22.04.2009
11:41 Uhr
Seite 12
the drill holes. Ensure that the equipment is secured
firmly and horizontally to the wall. Use only suitable
fastening material on a suitably stable wall. The
supplied dowels and screws are suitable for the
following: Concrete, natural stone with a dense
structure, solid brick, solid limestone bricks, solid
lightweight concrete bricks and aerated concrete.
Ensure that a minimum distance of 230 mm to the
sides and 450 mm to the top of the equipment are
maintained. See section 1 "Safety regulations".
Do not attach the feet if the equipment is to be
mounted on the wall.
When selecting the location for the appliance,
please note that if there are skirtings on the floor,
the minimum distance to the housing, or the
installation height, has to be measured from the
top of the skirting.
Then drill the two fastening holes with 8 mm
diameter. The centres of the holes must be
marked so that they are 415 mm apart and
230 V ~ 50 Hz
horizontal (3) and at least 550 mm above the
floor (allow for skirtings) and the holes must be
drilled accordingly.
Infinitely adjustable
Screw both shorter fixing brackets to the wall.
I
Instead of the feet, attach both of the remaining
longer fixing brackets with the shortest screws to
3 x 1 mm
2
the underside of the convector heater. These
serve as separators for the wall.
59 x 12 x 37.5 cm
Hang the convector heater on the wall and hang
the fixing brackets in the slots.
Note: The two bottom fixing brackets can also be
fastened to the wall. To do so, hang the convector
heater on the wall and drill holes in the wall to
correspond to the holes in the bottom fixing brackets.

6. Operation

Caution: Before using the equipment for the first
time, check that the voltage supply is the same as
the voltage details set out on the rating plate.
Read the safety regulations in section 1.
When the equipment is used for the first time or after
a long period of rest it may emit an odour for a short
time. This is not a fault.
6.1 Heat output switches (Fig. 1):
Low heat output – activate switch (Item 6)
Medium heat output – activate switch (Item 7 )
Maximum heat output – activate switch (Item 6)
and (Item 7)