Herunterladen Inhalt Inhalt Diese Seite drucken

Emerson A6150 Schnellstartanleitung Seite 18

Lagerschwingungsmonitor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product Information / Produktinformation A6150
Bearing Vibration Monitor
Dynamic outputs
The AC portion of the sensor signal is output as scaled value.
Channel 1 − AC1 / channel 2 − AC2
Nominal range
Measuring range
Precision
Frequency range
Per. load resistance
Internal resistance
*Depends on the jumper setting J2.
Scaled d.c. output
Note: Scaled d.c. outputs are not relevant and not to be used for the A6150!
Channel 1 − NGL1 / channel 2 − NGL2 z12 / d12 open circuit and short circuit proof, non
Nominal range
Per. load resistance
Internal resistance
Signal conditioning for characteristic values
The input signals are conditioned by adjusting amplifier, range−dependent amplifier, high
pass, and low pass prior to digitalization.
Range setting
Maximum measuring range
Frequency range
High pass filter
− Parameters can be set
− Tolerance
Low pass filter
Characteristic value formation
Vibration velocity
Vibration amplitude
z14 / z16* open circuit and short circuit proof, non
reactive
0 ... 20 V peak−peak
Corresponds to the measuring range configured for
the characteristic value (4V peak−peak)
±1
of f.s.d.
%
0.2 Hz ... 200 Hz (−3 dB) ±20
> 10 kΩ
Approximately 20 Ω
reactive
0 V DC
> 10 kΩ
Approximately 50 Ω
Is determined in the configuration
4.0V pp
Butterworth characteristic 2
fu: 0.2 Hz (−3 dB)
fu: 0.7 Hz (−3 dB)
±20 %
Butterworth characteristic 5
Range: 10Hz ... 200 Hz in 0.01 Hz increments
Depends on the configuration
Root mean square value v
frequency dependent integration of the vibration
velocity, signal evaluation in rms, zero − peak or
peak − peak
Page 18
%
nd
order
th
order
0−peak, peak−peak
rms,

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis