Product Information / Produktinformation A6150
Bearing Vibration Monitor

1.5.4 Installation

1. Check the slot wiring prior to installing the monitor.
2. Push the A6150 monitor into the prepared slot and press it with light pressure into the plug
connector.
3. Hand tighten the two anchoring screws on the front panel to secure the monitor.
Additional information regarding, e. g. shielding and grounding, configuration of the monitor,
etc., can be found in the direction for use of the A6125, order number: 6110−90069.
1.6

Configuration

i
Property sheet "Channel"
The parameters "Sensor type", "Sensitivity" and Impedance" will be automatically entered after
the sensor type selection via the button "Selection" in column "Permissible range".
Due to the required external supply of the LF sensors the parameters "Current setting" and
"Current supply" are greyed out an can't be used.
Property sheet "Data acquisition"
With the list field "Digital filter", one out of three different filter groups can be selected. The
following table shows these filter groups.
Parameter
"Digital filter"
Overall
Band 1
Band 2
Band 3
Band 4
The following section describes the property sheets and parameters of the
A6150 which are different to the A6125.
1
0.4 Hz − 200 Hz
0.4 Hz − 8 Hz
8 Hz − 15 Hz
15 Hz − 22 Hz
22 Hz − 100 Hz
2
0.4 Hz − 200 Hz
0.4 Hz − 200 Hz
0.4 Hz − 3.5 Hz
0.4 Hz − 3.5 Hz
3.5 Hz − 8 Hz
3.5 Hz − 8 Hz
8 Hz − 15 Hz
8 Hz − 15 Hz
15 Hz − 100 Hz
15 Hz − 30 Hz