Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Mounting; Sensor Connection - Emerson A6150 Schnellstartanleitung

Lagerschwingungsmonitor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product Information / Produktinformation A6150
Bearing Vibration Monitor
1.5

Installation and Mounting

A prepared 3U slot in a 19" rack, or other Intermas−compatible enclosure, is required for
mounting the A6150 monitor. The slot must be fitted with a 48−pin plug connector (DIN 41612,
design F 48 M). The pin assignment is listed in the following table.
2
UN+ (+ 24V)
4
A (RS 485)
6
not used
8
AIN2+ (Input)
10
AIN2− (Input)
12
NGL2 (scaled dc−output)
14
EO1 (voltage output1)
16
EO2 (voltage output2)
18
GWM (limit value)
20
NC
22
KEY−N (key signal input)
24
SC−A (oper. principle alert)
26
D1−C (danger1 collector)
28
D1−E (danger1 emitter)
30
D2−C (danger2 collector)
32
D2−E (danger2 emitter)

1.5.1 Sensor connection

The sensor LF−24/0.3Hz requires an external +/−15V DC voltage supply, e.g: Phoenix Mini−
PS−100−240AC/2X15DC/1. The following diagram shows the sensor connection including the
external sensor supply.
d
U− (0V/Common)
GND (BP, Common, RS 485) B (RS 485)
not used
not used
GND
GND
EI1 (voltage input1)
EI2 (voltage input2)
I1− (current output common)
I2− (current output common)
GND
GND
A1−C (alert1 collector)
A1−E (alert1 emitter)
A2−C (alert2 collector)
A2−E (alert2 emitter)
b
UB+ (+24V, redundant)
not used
AIN1+ (Input)
AIN1− (Input)
NGL1 (scaled dc−output)
AC1 (sensor raw signal1)
AC2 (sensor raw signal2)
I1+ (current output CH1)
I2+ (current output CH2)
ES (external lock)
SC−D (oper. principle danger)
CC1−C (ch. clear1 collector)
CC1−E (ch. clear1 emitter)
CC2−C (ch. clear2 collector)
CC2−E (ch. clear2 emitter)
Page 10
z
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis