2. Reserve a certain length of drain hose and
power cord for installation when binding
them. When binding to a certain degree,
separate the indoor power and then separate
the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound
separately at the end.
Notes:
• The power cord and control wire can't be crossed or winding.
• The drain hose should be bound at the bottom..
Step 9: hang the indoor unit
1.
Put the bound pipes in the wall pipe and then
make them pass trough the wall hole.
2. Hang the indoor unit on the wall-mounting
frame.
3. Stuff the gap between pipes and wall hole with
sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and
closed to the wall
Do not bend the drain hose too exces-
sively in order to prevent blocking.
connection pipe
indoor power cord
indoor
wall pipe
lower hook of
wall-mounting frame
drain hose
outdoor
sealing gum
upper hook
band