3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw and
then fix the power connection wire with wire
clip.
4. Put wiring cover back and then tighten the
screw.
5. Close the panel.
Notes
• All wires of indoor unit and outdoor unit should be connected by a professional. for a new one. Avoid
extending the wire by yourself.
• For the air conditioner without plug, an circuit break must be installed in the line.
• The air switch should be all-pole parting and the contact parting distance should be more than 3mm.
Step 8: bind up pipe
1.
Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
37
indoor and
outdoor power cord
gas
pipe
band
drain hose
liquid pipe
N(1)
2
3
blue
black
brown
yellow-
green
Outdoor unit connection