• The power cord and power connection wires can't be pressed by hard objects.
• If power cord or connection wire is broken, it must be replaced by a qualified person.
• If the power cord or connection wire is not long enough, please get the specialized power cord or
connection wire from the manufacture or distributor. Prohibit prolong the wire by yourself.
• For the air conditioner without plug, an air switch must be installed in the circuit. The air switch should be
all-pole parting and the contact parting distance should be more than 3mm.
• Make sure all wires and pipes are connected properly and the valves are opened before energizing.
• Check if there is electric leakage on the unit body. If yes, please eliminate the electric leakage.
• Replace the fuse with a new one of the same specification if it is burnt down; don't replace it with a cooper
wire or conducting wire.
• If the unit is to be installed in a humid place, the circuit breaker must be installed.
Installation Safety Precautions
• Select the installation location according to the requirement of this manual.(See the requirements in
installation part)
• Handle unit transportation with care; the unit should not be carried by only one person if it is more than
20 kg.
• When installing the indoor unit and outdoor unit, a sufficient fixing bolt must be installed; make sure the
installation support is firm.
• Ware safety belt if the height of working is above 2 m.
• Use equipped components or appointed components during installation.
• Make sure no foreign objects are left in the unit after finishing installation.
Refrigerant Safety Precautions
• Avoid contact between refrigerant and fire as it generates poisonous gas; Prohibit prolong the connection
pipe by welding.
• Apply specified refrigerant only. Never have it mixed with any other refrigerant. Never have air remain in
the refrigerant line as it may lead to rupture or other hazards.
• Make sure no refrigerant gas is leaking out when installation is completed.
• If there is refrigerant leakage, please take sufficientmeasure to minimize the density of refrigerant.
• Never touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite.