CALCULATION OF THE THERMAL POWER.

There is not an absolute rule for calculating the correct necessary power. This power is given according to
the space to be heated, but it depends also largely on the insulation. On an average, the calorific value
necessary for a properly insulated room is 40 kCal/h per m
Given that 1 kW corresponds to 860 kCal/h, it is possible to adopt a value of 50 W/m
Let's suppose that one wishes to heat a room of 150 m
necessary to have 150 m
Therefore as main heating, a 10 kW appliance is sufficient (see Table 5).
Fuel
Dry wood (15% humidity)
Wet wood (50% humidity)
Wood briquettes
Brown coal briquettes
Normal anthracite
Coke
Natural gas
Naphtha
Electricity
32
3
3
x 50 W/m
= 7500 W or 7.5 kW.
Unit
kg
kg
kg
kg
kg
kg
3
m
L
kW/h
3
(for an external temperature of 0 ° C).
3
(10 x 6 x 2.5 m) in an insulated apartment, it is
Approximate combustion
value
kCal
3600
1850
4000
4800
7700
6780
7800
8500
860
Table 5
Instructions for installation, use and maintenance Rev.01 - EN
INSERTO 50 – 80 – 100
3
.
Quantity required for 1 kg
of dry wood
kW
4.2
1.00
2.2
1.95
5.0
0.84
5.6
0.75
8.9
0.47
7.9
0.53
9.1
0.46
9.9
0.42
1.0
4.19