INSERTO 50 – 80 – 100
Thanks to a specific entry of the secondary air the building of deposit on the glass of the door is slowed
down in a remarkable way. However the building of this deposit cannot be avoided with the use of solid
fuels such as humid wood, and this is not to be considered as a defect of the appliance.
The correct process of ignition, the use of proper quantity and types of fuels, the right regulations of the
secondary air register along with a sufficient draught of the chimney with the presence of combustion air,
are essential for the optimal working of the appliance.
IMPORTANT:
The cleaning of the sight glass must be carried out only and exclusively with cold appliance to
avoid the explosion of the same.
For the cleaning, it is possible to use specific products or a wet newspaper paper ball passed in the
ash to rub the glass itself.
BREAK OF GLASSES:
Considering that the glasses are manufactured in glass-ceramic and resistant to heat shock up to
750 ° C, they are not subject to thermal shocks. The ir break can be caused only by mechanic shocks
(bumps or violent closure of the door, etc.). Therefore, their replacement is not included in the
warranty.
14.3.

CLEANING OF THE ASH

C
All the appliances are equipped with a hearth
grating and an ash drawer for the collection of the
ashes.
It is suggested to empty periodically the ash drawer
and to avoid it fills completely in order not to
overheat the grating. Moreover, it is suggested to
leave always 3-4 cm of ash in the hearth.
B
The ashes removed from the hearth have to be
stored in a container made of fire-resistant material
equipped with an air-tight cover.
A
The container has to be placed on a fire-resistant
Figure 17
floor, far from flammable materials up to the
switching off and complete cooling.
Check the external air intake, by cleaning it, at least once a year.
The stack must be regularly swept by the chimney sweeper.
Let your chimney sweeper in charge of your area check the regular installation of the appliance, the
connection to the stack and the aeration.
15.

SUMMER TIME

After having performed the cleaning of the hearth, of the stack and of the flue, by removing completely the
ash and other possible residuals, close all hearth doors and related registers.
It is suggested to perform the flue cleaning at least once a year; in the meantime, verify the actual state of
the door seals, which do not assure the good operation of the appliance, if they are not completely integral
(i.e. if they do not adhere anymore to the door)! Therefore, it is necessary to replace them.
In case of humidity of the room where the appliance is located, place the absorbing salts within the hearth.
Protect the internal cast iron parts with neutral Vaseline, if you wish to keep the aesthetic appearance
unchanged in time.